Functional Message Troubleshooting - Panduit PAT1M4.0 Operation Manual

Automatic cable tie installation tools pdm4.0: dispenser phm: feeder hoses
Table of Contents

Advertisement

© Panduit Corp. 2018
MESSAGE
ERROR 12
Tie stuck in tool
sensor
ERROR 13
Detent sensor
blocked or dirty
ERROR 14
Internal regulator
incorrectly set, low
ERROR 15
Internal regulator
incorrectly set, high
ERROR 16
Tie stuck in gripper
ERROR 17
Full tip collector
*If the cable tie does not come out freely, turn the dispenser "off" and then "on" again to reset the rotary receiver's position.
12B: Functional Message Troubleshooting
MESSAGE
No exit sensor
Cable tie in feeder hose when tool was
seen - service
actuated or dispenser exit sensor is
tool soon
not functioning properly.
Trigger
The trigger was held down or was
Malfunction
stuck when the dispenser was turned
"on". This message will remain if the
trigger switch has malfunctioned.
Jaw sensor
Cable tie stopped in tool gears.
error
Dispenser
Sensor is not functioning correctly.
Sensor
Tie Sensor
See Page 50.
PA27647A01_05
OPERATION MANUAL
ENGLISH
POSSIBLE CAUSE
Cable tie has stopped in the tool
sensor area of tool.
Tip collector full. Detent sensor
blocked by detent cam, foreign
object, or detent sensor lens is
dirty.
Internal regulator was adjusted in-
correctly, or the piston is not fully
shifting.
Internal regulator was adjusted
incorrectly.
Excessive humidity or dry ties with
high tool tension
Tip collector counter has reached
maximum number of tips
POSSIBLE CAUSE
Page: 57 of 64
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
CORRECTIVE ACTION
1. Press "Silence" icon to silence the alarm.
2. Follow corrective action for "Blocked or dirty tool sensor"
error above.
1. Press "Silence" icon to silence the alarm.
2. Remove cable tie from jaw area of tool.
3. Press the "Back" icon and resume operation.
4. If message reappears, notify maintenance department.
1. Press "Silence" icon to silence the alarm and resume
operation.
2. If message remains, system will not operate. Write down
message and notify maintenance department.
1. Press "Silence" icon to silence the alarm.
2. Lower the tension setting on the tool.
3. Pull trigger to complete cycle
4. Reset tension
1. Press "Silence" icon to silence the alarm.
2. Remove tip collector and empty.
3. Re- attach the tip collector
4. Press "Back" to reset the internal counter
CORRECTIVE ACTION
1. Resume operation.
2. If the same error is repeated, the exit sensor lens may be
dirty, or it may not be functioning properly.
3. Clean the exit sensor lens (Refer to the Cleaning the
Dispenser Exit Sensor Lens section on Page 53).
4. If the same error is repeated, notify your maintenance
department.
1. The message will disappear when the trigger has been freed
or released.
2. If the message does not disappear, then the trigger is bad.
Contact your maintenance department to have the trigger
switch replaced.
1. Press "Silence" icon to turn buzzer "off".
2. Remove the cable tie from the jaw area.
3. Press the "Continue" icon and resume operation.
1. Press the "Back" icon and resume operation.
2. If the dame error is repeated, notify your maintenance
department.
See Page 50
12-2018