6: Technical Specifications; Air Supply; Electrical Specifications - Panduit PAT1M4.0 Operation Manual

Automatic cable tie installation tools pdm4.0: dispenser phm: feeder hoses
Table of Contents

Advertisement

© Panduit Corp. 2018

6: TECHNICAL SPECIFICATIONS

6A: Air Supply
Recommended regulated air pressure to dispenser
(pressures other than recommended may result in
unsatisfactory operation):
Air consumption at 25 cycles per minute
Line pressure to regulator:
Filter/regulator requirements:
Lubrication for air supply:
Recommended filter/regulator unit (supplied by user)
3/8" NPT ports:
Recommended main air supply hose from
filter/regulator to dispenser (supplied by user):
Recommended female quick disconnect for main air
supply (supplied by user): The dispenser is furnished
with a male quick connect plug that will fit female
interchangeable couplers.
6B: Electrical Specifications
ITEM
Line Voltage (PDM4.0 Dispenser)
Power
Phase
Line Fuse(s)
Power to Tool
This unit includes EMI/RFI filters, however it is possible that infrequent electrical phenomena may cause tool function to be
temporarily interrupted. This interruption can be corrected by turning the tool "off" (removing the cable tie if necessary), and
then back "on" again.
PA27647A01_05
OPERATION MANUAL
ENGLISH
ITEM
MODEL
All
All
All
All
All
Page: 12 of 64
MIN.: 65 PSIG (4,5 bar)
MAX: DO NOT EXCEED 85 PSI (5,8 bar).
Max. recommended pressure drop:10 PSI (0,7 bar)
7 cfm @ 65 PSIG (3,3 l/sec @ 4,5 bar)
Minimum 70 PSIG (4,8 bar),
Maximum 125 PSIG (8,5 bar)
40 micron maximum element rating
5 PSI (0,3 bar) maximum pressure drop @
70 PSIG (4,8 bar) inlet pressure
12 cfm (5,7 l/sec) flow minimum.
Air line lubricators are NOT to be used. Lubricators
will damage internal system components and seals.
Recommended source:
Panduit Part Number PL283N1 (See Page 8)
Recommended source:
Panduit Part Number PDH10-37 (See Page 8)
1/4" female industrial quick disconnect coupling
DESCRIPTION
100 / 115 / 230 V (50/60 Hz)
300 W
Single Phase
F1 4 A, 250 VAC (1) – Main Power
F2 4 A, 250VAC (1) – Backup Power
Panduit Part Number (for both fuses): CA21138A01
Logic -- 5 V
. 250 mA
Motor – 25 Watt
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
DESCRIPTION
12-2018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5m4.0Pat1m4.0-btPat1.5m4.0-bt