2. Press the "Tie Type" icon
set the correct internal regulator pressure per the tie type (1M or 1.5M).
The dispenser comes preset for 1M ties from the factory. Verify that the convey pressure is indeed within range for
the tie being used. If it is not, open the side door as shown in Fig. 12 and locate the internal regulator as shown in
Fig. 13. Adjust the convey pressure up or down by manually pulling up on the regulator cap and turning the regulator
either clockwise or counterclockwise respectively. Press the "Back" icon to return to the ready screen followed by
pressing the "Tie Type" icon again. The system will perform a backpressure test before displaying the newly set
convey pressure. Repeat if further adjustment is needed. Once the desire convey pressure is met, push down on
the regulator cap to lock it from further adjustment. Close the dispenser door. Press the back button three times
to return to the Ready Menu. The system is ready to load XMR cable ties.
7E: Loading XMR Cable Ties
1. Remove the cable tie reel from the protective re-sealable plastic bag. Note: Save the bag for tie storage.
Remove the corrugated cardboard wrap from around the cable ties. Inspect the tie reel for distorted or damaged
ties and remove as needed but cutting cable ties from carrier strip. Carefully slide the cable tie reel onto the
reel axle so that the reel turns clockwise as the cable ties are dispensed. Slide collar onto the reel mount
assembly with the thumb screw toward the installer. Push collar in compressing the spring on the reel mount
a minimum of ¼". Tighten the thumb screw by hand only – Do Not use tools. Remove the cellophane tape
from the end of the cable tie strip and discard.
PA27647A01_05
OPERATION MANUAL
ENGLISH
and the system will advance to the convey pressure screen to help the user
MAINTENANCE > SET> CONVEY
PSI
BAR
CONVEY
47
3.24
TIE PRESSURE RANGE
1M
47 - 52
3.2 - 3.6
1.5M
37 - 42
2.6 - 2.9
Fig. 12
Page: 17 of 64
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
10
BACK
Fig. 13
12-2018