Cleaning The Dispenser Tie And Exit Sensor Lens; Touch Screen Calibration - Panduit PAT1M4.0 Operation Manual

Automatic cable tie installation tools pdm4.0: dispenser phm: feeder hoses
Table of Contents

Advertisement

© Panduit Corp. 2018
10C: Cleaning the Dispenser Tie and Exit Sensor Lens
Disconnect the PHM Feeder Hose from the PDM Dispenser. Dampen one end of a cotton swab with isopropyl
alcohol and insert the dampened end of the cotton swab into the dispenser transfer tube about 1.5" (38 mm) and
gently move the cotton swab in and out, against the top and bottom walls of the transfer tube until clean.
Reconnect the feeder hose to the dispenser and resume operation.
Disconnect power to the PDM4.0 Dispenser. Disconnect the PHM Feeder Hose from the PDM4.0 Dispenser. Use
air to blow out the internal debris from the bottom port underneath the dispenser. This will clear the tie sensor
located on the rear plate assembly.
10D: Touch Screen Calibration
Touch screen calibration may be required due to changes in environment conditions and variations in resistance
coating over time thru wear. Environmental conditions such as temperature and humility can alter the resistance
characteristics therefore, affecting the position measurements of the touch screen.
Tap the touchscreen display 20 times within 4 seconds in a non- button area to activate calibration mode.
Calibration mode is signaled by a long beep from the display buzzer preceding a solid blue screen. Click "X"
positions on the touch screen to calibrate. When the calibration is complete, the system will return to the "Ready"
screen.
PA27647A01_05
OPERATION MANUAL
ENGLISH
Page: 53 of 64
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
12-2018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5m4.0Pat1m4.0-btPat1.5m4.0-bt

Table of Contents