Sensing Edge Wiring - Genie GCL-J&H 1/2HP Installation Manual

Standard duty operator
Table of Contents

Advertisement

Sensing Edge Installation (continued)
7)
Operate the door to make certain cord is free to travel and does not become
snared during door opening or closing.
Check sensing edge for proper operation.
8)
While the door is closing actuate the sensing edge to verify the door reverses to open limit.
Figure 12
shows the connection of OPAKMMWE.S MEL Miller Edge Monitored Wireless Sensing Edge.
PWR
20-40 VDC @ 250mA
MAX. CURRENT
EXT RADIO
CONNECTOR
WARNING:
must be set to a unique address. Follow instructions provided with the Miller Edge MEL kit to set the address.
AVERTISSEMENT:
bord MEL, réglez chaque ensemble émetteur/récepteur sur une adresse unique. Suivez les instructions fournies
avec le kit Miller Edge MEL pour définir l'adresse.
Figure 12
YELLOW
GND
ORANGE
RELAY
BLUE
NOM
+24VDC
To obtain proper operation of the MEL edge sensor, each transmitter/receiver set
Pour obtenir un fonctionnement correct du capteur de
www.geniecompany.com
CONTROL SIGNAL TERMINAL STRIP
ODC
ODC
STB
STB
WHT
GRN
BLK
RED
WIRELESS
EDGE RECEIVER
WIRE NUT
SENSING EDGE
WIRELESS EDGE
TRANSMITTER
04-14
5.10