Setting Mid-Stop Limit

The Operator includes a programmable Mid-Stop. This feature allows the operator
to stop at a user selectable point when opening. It is used when operating very tall doors
that only open to their full height occasionally. The Mid-Stop does not effect the operator
when closing. To operate door to full open position from mid-stop, press open button again.
NOTE: Setting of the MID-STOP should only be performed AFTER Travel
Limit and Max Run Timer settings have been made.
CAL
1) Press CAL/RUN
key to enter calibration mode.
RUN
2) Press the CLOSE
key to close the door to the down limit.
CLOSE
key until display reads "MID-STOP > CLR" Figure 14.
3) Press SCROLL
SCROLL
NOTE: If the display reads MID-STOP > SET at this point, first clear the
MID-STOP as described below then repeat steps 1-3 and continue.
4) Press the OPEN
key to open the door to desired mid-stop height.
OPEN
keyuntil the display reads "MID-STOP > SET"
5) Press SET/CLEAR
SET
CLEAR
6) Press CAL/RUN
CAL
key to return to run mode.
RUN
To CLEAR the Limit
CAL
7) Press CAL/RUN
to enter calibration mode.
RUN
until display reads "MID-STOP > SET"
8) Press SCROLL
SCROLL
until the display reads "MID-STOP > CLR"
9) Press SET/CLEAR
SET
CLEAR
10) Press CAL/RUN
CAL
to return to run mode.
RUN
www.geniecompany.com
OPEN
MID-STOP CLR
CLOSE
STOP
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 14