The latch can come loose from glass frame anchor. This occurs when it is turned 1/4 turn when it is
disengaged. Follow the directions below to re-install the latch if it becomes loose.
Hold the latch at an angle and insert it into the slot on the glass frame anchor.
Glass Frame
Anchor
Note how the washer on the latch fits behind the flange on the
glass frame anchor.
Once fully inserted, turn the latch until it is upright.
© Travis Industries
Installation
(for qualified installers only)
Latch
NOTE: this slot may be at a
different angle than illustrated.
Top of
Firebox
1/2/19 - 1458