Remove High Temp Operating Thermostat And Bias Heater - Maytag MDE17CS Service Manual

New dependable care commercial single and stack gas and electric dryers 50 hertz models
Hide thumbs Also See for MDE17CS:
Table of Contents

Advertisement

rEMOvE HiGH TEMP OPEraTiNG THErMOSTaT
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove lower service panel
(See page 4-21).
2.
Remove four wire connectors from the high
temp thermostat and bias heater.
Four Wire
Connectors
3.
Remove two 1/4" hex head screws that
secure the thermostat to the top of the
blower housing.
Two 1/4" Hex
Head Screws
aND BiaS HEaTEr
4.
The smaller center terminals are for the bias
heater within the thermostat which allows
the dryer to run at medium temperature.
NOTE: These screws are very short so
as not to protrude into the blower housing
where they could catch lint.
4-28
Bias Heater
Terminals

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mdg17csMde17mnMle24pnMdg17mnMlg24pnMlg24pd ... Show all

Table of Contents