Remove The Collar - Maytag MDE17CS Service Manual

New dependable care commercial single and stack gas and electric dryers 50 hertz models
Hide thumbs Also See for MDE17CS:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the upper dryer (See page 4-58).
2.
Remove the control board bracket.
(See page 4-50).
3.
Disconnect all connectors from control
board.
4.
Remove motor relays. (See page 4-53).
5.
Remove transformer. (See page 4-54).
6.
Remove power connector to lower dryer.
(See page 4-60).
7.
Remove the terminal block
(See page 4-60).
8.
Remove power leads from the terminal
block. (See page 4-61).
9.
Pass the power leads through the holes in
the collar into the back part of the dryer and
lay them on the dryer drum.
10.
Remove the coin vault switch.
(See page 4-61).
11.
Remove the coin drop. (See page 4-62).
12.
Remove the service switch assembly.
(See page 4-55).

rEMOvE THE COllar

4-64
13.
Remove the Earth wires from the collar
(See page 4-63).
14.
Remove the coin vault. (See page 4-62).
15.
Remove four 1/4" hex head screws that
secure the collar to the lower dryer
Four 1/4" Hex
Head Screws
16.
Remove two 1/2" hex head bolts that
secure the collar to the lower dryer.
NOTE: These bolts go from the lower dryer
up into the collar. The other bolt is located
on the opposite side of the dryer and is not
visible to show removal. Access it from
the inside rear of the collar just like the one
shown here through the coin vault area.
17.
Lift the collar off of the lower dryer.
1/2" Hex
Head Bolt