CRS-311 1:1 Redundancy Switch
Modem, RMI/TMI, and Switch Configuration

Table 4-2. CRS-515 TMI Factory-configured Jumper Settings

 
Modem Jumper 'JMP3'
Control Setting
SLM-
5650/5650A
AS SHIPPED
CDM-750
 
4.5

Switch Configuration

4.5.1 Switch Power

Follow these steps to connect the power cords: 
 
Step
Task
Each CRS-311 is supplied with two power cords. Connect the female end of the supplied
1
power cords (one to each power supply power input).
Plug both power cords into the power source(s). The CRS-311 will power ON.
2
Note: The auto-sensing power supplies do not require any adjustments.
 
If only one power supply module is used, mask the fault for the unused power supply as follows: 
 
Step
Task
1
Go to the CONFIG: MASKS
2
Select to mask the unused power supply.
The power supplies contain two fuses, one each for line and neutral connections 
(or L1, L2 where appropriate). These are contained within the body of the 
connector, behind the small plastic flap. 
 
For continued operator safety, always replace the fuses with the correct type and 
rating. For 115/230 volt AC operation, use T1A (slow‐blow) 20 mm fuses. 
 
 
Jumpers
Settings
Pins
1 to 2
jumped
Pins
3 to 4
jumped
SW-ALARMS menu.
4–10
Switch Jumper 'JMP1'
Control Setting
Jumpers
CRS-311
AS SHIPPED
CRS-500
Revision 7
MN/CRS311.IOM
Settings
Pins
3 to 4
jumped
Pins
1 to 2
jumped