Monitor; Monitor:) Status; Monitor:) Sw-Alarm - Comtech EF Data CRS-311 Installation And Operation Manual

1:1 redundancy switch, accessory product for use only with comtech ef data cdm-qx/qxl and slm-5650/5650a modems (modem firmware and hardware requirements apply)
Table of Contents

Advertisement

CRS-311 1:1 Redundancy Switch
Front Panel Operation

5.2.4 MONITOR

MONITOR:
STATUS
STORED-EVENTS
 
Use the ◄►arrow keys to select STATUS, SW‐ALARM, STORED‐EVENTS, COMMs (COMM‐
STATE), or IO, and then press ENTER. 
5.2.4.1

(MONITOR:) STATUS

TRAFFIC MODEM IS ONLINE.
BACKUP HOLDOFF: 05 SEC
 
This submenu displays the Switch status as follows: 
 
If Auto Mode is ON, it will also show the backup holdoff time should the bridged Traffic 
Modem fail.  
 
If Auto Mode is OFF, the second line displays "OFF". Once the Switch takes the Traffic 
Modem  offline  and  replaces  it  with  the  Redundant  Modem  –  whether  manually  or 
automatically – the screen changes as follows: 
 
REDUNDANT IS ONLINE.
RESTORE HOLDOFF:
 
The restore holdoff time displays on the second line if Auto Mode is ON. 
5.2.4.2

(MONITOR:) SW-ALARM

SWITCH ALARM:
 
This  Switch  Alarm  screen  example  shows  that  there  are  no  faults;  accordingly,  the  front  panel 
"Unit Status" LED indicator is lit GREEN. 
 
SWITCH ALARM:
IS UNDERVOLTAGE
 
This Switch Alarm screen example shows that there is a fault – Power Supply "B" is under voltage; 
accordingly, the front panel "Unit Status" LED indicator is lit RED. 
 
Suggested corrective actions include:  
 
Ensure power supply power cord is connected and the power switch is ON;  
 
SW-ALARM
COMMS
IO
05 SEC
NONE
-12V PS-B
5–13
Revision 7