Comtech EF Data CRS-311 Installation And Operation Manual page 188

1:1 redundancy switch, accessory product for use only with comtech ef data cdm-qx/qxl and slm-5650/5650a modems (modem firmware and hardware requirements apply)
Table of Contents

Advertisement

CRS-311 1:1 Redundancy Switch
Appendix D
 
d. The "Stored Event" LED on the CRS‐311 Front Panel will flash at twice the current rate when 
Independent Mode is enabled. 
 
e. Independent Mode is selectable via the Front Panel menu or remote control command: 
 
i.
To configure via the CRS‐311 Front Panel menu:  
 
Use  the  ◄  ►arrow  keys  to  select  UTIL
[ENTER];  
 
Use the ◄ ►arrow keys to select NORMAL-OP or ENABLE-INDEP, and then press 
[ENTER]. 
 
ii. To  configure  via  remote  control  command:  IMS=x,  where:  x=0  (Independent  Mode 
disabled) or x=1 (Independent Mode enabled). 
 
Traffic
Data
M&C
(RS232/485)
 
Data #2
(RS232/485)
 
Redundant
CRS-311
5650
Baseband
Primary
5650
Figure D-1. Standard Connections to CRS-311
Traffic
Redundant
CRS-311
Baseband
Traffic
Data #1
Always to
Primary
M&C
Figure D-2: CRS-311 in Independent Mode
CRS-311 IF
÷
 
CRS-311 IF
÷
5650
Primary
5650
D–2
MN/CRS311.IOM
INDEP-MODE,  and  then  press 
Return
Forward
Link
Link
C1
C1
RL C1 & C2
Forward
Return
Link
Link
C1
C2
C1
C2
FL C2
Switched
to Redundant
FL C1
Revision 7

Advertisement

Table of Contents
loading