Installation
To avoid injury due to unexpected moving parts,
remove power to the pumpjack and wait for the walk-
ing beam to stop moving before performing any task
on the G-Chem pump. The G-Chem pump is directly
influenced by the motion of the pumpjack's walking
beam, and the pump is inactive only when the walking
beam is unable to move.

Grounding

The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
Pump: grounded through fluid lines.
Fluid lines: use only electrically conductive lines.
Fluid supply container: follow local code.

Accessories

Install the following required accessories in the order
shown in a typical installation (see F
using adapters as necessary.
Fluid filter (Y-Strainer) (included in K): with a 60
mesh (250 micron) stainless steel element to filter
particles from the fluid before in reaches the pump.
Fluid shutoff valves (L): shuts off fluid flow.
Pressure relief valve (D): overload protection.

Flush Before Using Equipment

The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
Flush the Equipment, page 12.
8

Typical Installation

F
chemical injection beam pump. Your installation may dif-
fer from what is shown here. (See Accessories on
page 8.) The G-Chem beam pump (A) and the swivel
block (B) are the only components in F
Graco. All other components are supplied by customer.
Key:
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
. 3 on page 9)
IG
. 3 is an example of an installation with a G-Chem
IG
G-Chem Beam Pump
Swivel Block and Eye Bolt
Tank
Pressure Relief Valve (Required)
Inlet Line
Outlet Line
Pressure Relief Line
Inlet Port
Outlet Port
Manifold Assembly (includes y-strainer and fluid shutoff
valve (L))
Fluid Shutoff Valve (inlet & outlet) (Required)
Pumpjack Base (I-Beam)
Cable/Rod/Pipe
Walking Beam
Beam Clamp
. 3 supplied by
IG
3A6349A

Advertisement

Table of Contents
loading

Table of Contents