Typical Installation; Installation - Graco Dyna-Star 236-753 Instructions And Parts List

Hydraulic reciprocator & pump
Hide thumbs Also See for Dyna-Star 236-753:
Table of Contents

Advertisement

Typical Installation – Suction Feed System
KEY
A
Hydraulic Fluid Control, 236–864
(See Manual 308–395)
B
Porous Plug (Weep tube optional)
C
Fluid Dispenser Outlet
D
Drain Valve (Required)
F
Hydraulic Return Line
G
Hydraulic Outlet, 3/4 npt
Fig. 1
The installation shown above is only a guide. For assis-
tance in designing a system to suit your needs, contact
your Graco representative.
Mount the pump to suit the type of installation planned.
See page 22 for Accessories.
WARNING
Maximum Working Pressure of Accessories
To reduce the risk of serious bodily injury including
fluid injection and splashing in the eyes or on the
skin, which may be caused if a component ruptures,
all accessories added to the reciprocator power
supply side must have at least a 1500 psi (105 bar)
maximum working pressure and those to the pump
fluid outlet side must have at least a 375 psi (26 bar)
maximum working pressure.
Pump Accessories
Suction Tube Kit A suction tube kit is available for si-
phoning from 55 gallon containers.
Intake T ube (not shown) To install, apply
the female threads at the top of the tube. Screw the tube
tightly onto the intake housing of the stubby pump.

Installation

F
K
M
N
J
S
H
Return Line Shutoff Valve
J
Hydraulic Inlet, 3/8 npt
K
Hydraulic Supply Line Shutoff
Valve
L
Pressure Gauge
M
Pressure Reducing Valve
N
Flow Control Valve
PTFE
tape to
P
H
A
L
G
R
C
B
D
Q
P
Hydraulic Supply Line (Use only
GRACO hydraulic power supply)
Q
Material Supply
R
Ground Wire (Required)
S
Wall Mounting Bracket 236–778
(See Manual 308–394)
Low–level Cutoff Valve To install, screw the low–level
cutoff valve into the bottom of the pump intake tube or the
suction tube. This valve closes the pump intake when the
fluid level is low, causing the pump to stall to avoid run-
ning dry.
WARNING
Pump Outlet Drain Valve
A pump outlet drain valve (D) is required in your sys-
tem. This valve helps relieve pressure in the dis-
placement pump and hose when shutting down the
system and in case of a clogged outlet hose. Install
the valve close to the pump outlet.
Pump Outlet Drain V alve Install a drain valve (D) close
to the pump fluid outlet to assist in relieving fluid pressure
in the pump when the pump is shut off.
Ground Wire A ground wire is required. See Acesso-
ries, page 22.