Technical Data - Siemens SIMATIC NET PROFIBUS Owner's Manual

Siemens network system owner manual
Table of Contents

Advertisement

7 Technical Data

7 Technical Data
OLM Module
Voltage/power supply
Operating voltage
Current consumption
Output voltage/current for terminal
resistors (Pin 6 Sub-D socket)
Signaling contact
Maximum switch voltage
Maximum switch current
Signal transmission
Transmission rate
Setting transmission rate
Bit error rate
Signal processing time (any input/output)
Retimer
Input Port 1 to 3
Signal distortion
Bit length
Output Port 1 to 3
Mean bit length
Safety
VDE regulation
UL/CSA approval
FM approval
Electrical port
Input/output signal
Input dielectric strength
PIN assignment, port 1
Indirect-coupled
Optical ports
Wavelength
Launchable optical power
– in glass fiber E 10/125
– in glass fiber G 50/125
– in glass fiber G 62.5/125
– in PCF fiber S 200/230
transmitting power "Reduced"
transmitting power "Default"
– in plastic fiber S 980/1000
transmitting power "Reduced"
transmitting power "Default"
Receiver sensitivity
Receiver overload
Version 1.0 8/00
P11
G11
P12
G12
G12-EEC
18 V to 32 V DC, typ. 24 V, (redundant inputs uncoupled),
safety extra-low voltage, indirect-coupled
max. 200 mA
5 V + 5%, – 10% / 90 mA; short circuit-proof
60 V DC; 42 V AC (safety extra-low voltage)
1.0 A
9.6; 19.2; 45.45; 93.75; 187.5; 500 kBit/s
1.5; 3; 6; 12 Mbit/s
automatic
-9
< 10
6.5 t
Bit
± 30 %
± 0.12 %
± 0.01 %
VDE 0806 = EN 60950 and IEC 950
UL 1950/CSA 950
in preparation (Class 2)
RS 485 level
– 10 V to + 15 V
in accordance with EN 50170 Part 1
yes, within SELV limits
660 nm
860 nm
– 15 dBm
– 13 dBm
– 17 dBm
– 9.5 dBm
– 5 dBm
– 25 dBm
– 28 dBm
– 3 dBm
– 3 dBm
G11-1300
G12-1300
1310 nm
– 19 dBm
– 17 dBm
– 17 dBm
– 29 dBm
– 3 dBm
31