Siemens SIMATIC NET PROFIBUS Owner's Manual page 299

Siemens network system owner manual
Table of Contents

Advertisement

SIMATIC NET PROFIBUS Plastic Fiber Optic
Fitting Simplex Connectors
Insert the cord into the simplex plug as
far as it will go Œ and close the clamp •.
Caution: The fiber must extend at least
1.5 mm beyond the end face of the
connector.
Grinding and Polishing Simplex Connectors
Cut off excessive fiber with scissors
leaving approximately 1.5 mm in length.
The polishing is completed when the
fiber is flush with the end face of the
connector.
Remove the debris from the polishing
holder and from the end face of the
connector using a clean cloth.
Installation Instructions for Simplex Connectors
Close the clamp until you hear the catch
lock in place.
Insert the simplex connector into the
polishing holder as far as it will go.
Then polish the end face of the
connector by describing figures-of-eight
on the pink polishing foil (rough side).
Repeat the figure-of-eight movement
approximately 25 times.
Polishing reduces the attenuation by
approximately 2 dB (corresponds to
approximately 10 m cable length). With
short lengths of cable polishing is
unnecessary.
Page 9
Repeat the same procedure for the
second cord.
Caution: Do not insert the connector into
a device socket, otherwise the excess
fiber length is liable to damage the
transmitter and receiver elements.
Grind down the excess fiber by
describing a figure-of-eight on polishing
paper (600 grit) on a flat solid surface.
Repeat the procedure with the second
connector and clean the surfaces of the
plug with a clean cloth.

Hide quick links:

Advertisement

Table of Contents
loading