AS-Interface Slaves
AS-Interface for LOGO!
■
Overview
Each LOGO! now connectable to the AS-Interface system
-new-
6
■
Technical specifications
Supply voltage in V
Inputs/outputs
Bus connection
Ambient temperature in °C
Degree of protection
Mounting
Dimensions (W x H x D) in mm
Display of LEDs
■
Selection and Ordering data
3RK1 400-0CE10-0AA2
6/134
Siemens IK PI · 2004
Design
AS-Interface connection for LOGO!
With the AS-Interface for LOGO! an intelligent slave can be inte-
grated into the AS-Interface system. Modular integration permits
different basic units to be integrated into the system whenever
the functionality is required. The functionality can also be quickly
and easily adapted to changing requirements by replacing the
basic unit
The interface provides four inputs and four outputs for the sys-
tem These I/Os, however, are not actually implemented in hard-
ware; they only exist virtually via the interface on the bus
24 V DC
4 / 4
(virtual inputs / outputs)
AS-Interface according to specification
0 to +55
IP20
onto standard mounting rail
36 x 90 x 58
LEDs
green
red
red/yellow flash
Status
OK
No data traffic
Zero address
Order No.
3RK1 400-0CE10-0AA2