Technical specifications (continued)
SlimLine S22.5
Total current input in mA
Inputs
• Sensor supply via AS-Interface
• Voltage range in V
• Current carrying capacity
for sensor supply in mA
• Connection of sensors
• Switching level High in V
• Input current Low/High in mA
I/O configuration
ID/ID2 code
Assignment of data bits
• Data bit D0
• Data bit D1
• Data bit D2
• Data bit D3
Connection
Total current input in mA
Inputs
• Sensor supply via AS-Interface
• Voltage range in V
• Current carrying capacity
for sensor supply in mA
• Connection of sensors
• Switching level High in V
• Input current Low/High in mA
I/O configuration
ID/ID2 code
Assignment of data bits
• Data bit D0
• Data bit D1
• Data bit D2
• Data bit D3
Connection
Conductor cross-sections in mm
Note
I/O modules for operation in IP20 control cabinet
4 inputs
Screw-type connection
Standard slave
2-wire
3RK1 200-0CE00-0AA2
50
Short circuit and overload
withstand capability
20 to 30
--
2-wire system
³
10
³
1.5 /
5
0
0/F
IN1
IN2
IN3
IN4
Via screw terminal
4 inputs
Spring-loaded connection
Standard slave
2-wire
3RK1 200-0CG00-0AA2
50
Short-circuit and overload
withstand capability
20 to 30
--
2-wire system
³
10
³
1.5 /
5
0
0/F
IN1
IN2
IN3
IN4
Spring-loaded terminal connection
2
´
Solid: 2
(0.25–1.5)
Finely stranded with end sleeve:
´
2
(0.25–1)
Finely stranded without end sleeve:
´
2
(0.25–1.5)
AWG conductor connections solid
´
or stranded: AWG 2
(24–16)
Disassembly tool for spring-
loaded terminal connection:
See "Accessories"
AS-Interface Slaves
4 inputs
Screw-type connection
Standard slave
2- and 3-wire
3RK1 200-0CE02-0AA2
270
Short circuit and overload
withstand capability
20 to 30
200
2- and 3-wire system
³
10
³
1.5 /
5
0
0/F
IN1
IN2
IN3
IN4
Via screw terminal
4 inputs
Spring-loaded connection
Standard slave
2- and 3-wire
3RK1 200-0CG02-0AA2
270
Short-circuit and overload
withstand capability
20 to 30
200
2- and 3-wire system
³
10
³
1.5 /
5
0
0/F
IN1
IN2
IN3
IN4
Spring-loaded terminal connection
´
Solid: 2
(0.25–1.5)
Finely stranded with end sleeve:
´
2
(0.25–1)
Finely stranded without end sleeve:
´
2
(0.25–1.5)
AWG conductor connections solid
´
or stranded: AWG 2
(24–16)
Disassembly tool for spring-
loaded terminal connection:
See "Accessories"
SlimLine
4 inputs
new
Screw-type connection
A/B slave
2- and 3-wire
3RK2 200-0CE02-0AA2
270
Short circuit and overload
withstand capability
20 to 30
200
2- and 3-wire system
³
10
³
1.5 /
5
0
A/0
IN1
IN2
IN3
IN4
Via screw terminal
4 inputs
new
Spring-loaded connection
A/B slave
2- and 3-wire
3RK2 200-0CG02-0AA2
270
Short-circuit and overload
withstand capability
20 to 30
200
2- and 3-wire system
³
10
³
1.5 /
5
0
A/0
IN1
IN2
IN3
IN4
Spring-loaded terminal connection
´
Solid: 2
(0.25–1.5)
Finely stranded with end sleeve:
´
2
(0.25–1)
Finely stranded without end sleeve:
´
2
(0.25–1.5)
AWG conductor connections solid
´
or stranded: AWG 2
(24–16)
Disassembly tool for spring-
loaded terminal connection:
See "Accessories"