AS-Interface Slaves
I/O modules for operation in the field
Digital I/O modules IP67 - K60
Technical specifications
Technical specifications common to all IP67 – K60 digital I/O modules
Operational voltage in accordance
with AS-Interface specification in V
Input connection
Inputs
• Sensor supply via AS-Interface
• Sensors
• Voltage range in V
• Current carrying capacity f
or all inputs (T
40 °C) in mA
u
• Switching level High in V
• Input current Low/High in mA
Outputs
• Type of output
• Short-circuit protection
• Inductive interference protection
(free-wheeling diode)
• External 24 V DC supply voltage
• Watchdog
AS-Interface certificate
Approvals
6
Total current input in mA
Socket assignment, inputs
Outputs
• Current carrying capacity per
output in A DC 12 / DC 13 typ.
• Maximum summation current
per module in A
• Socket assignment, outputs
I/O configuration
ID/ID2 code
Assignment of data bits
• Socket 1
• Socket 2
• Socket 3
• Socket 4
• Socket 5
• Socket 6
• Socket 7
• Socket 8
Number of I/O sockets
Note
6/44
Siemens IK PI · 2004
26.5 to 31.6
PNP
Short-circuit and overload
withstand capability
2- and 3-wire
20 to 30
200
³
10
³
1.5 /
6
Electronics
Built-in
Built-in
Over black AS-Interface flat cable
Built-in
Available (or under application
in the case of new products)
UL, CSA, marine certification
(or under application in the case
of new products)
8 inputs/2 outputs
2 A
A/B slave
Special assignment
3RK2 400–1HQ00–0AA3
300
PIN 1 = Sensor supply L+
PIN 2 = Data input II
PIN 3 = Sensor supply L-
PIN 4 = Data input I
PIN 5 = Earth connection
2
4
3 = "-"
4 = Output
5 = Ground connection
0 (Addr. 1) / 7 (Addr. 2)
A/E (Addr. 1 and 2)
PIN4 = IN1(D0) (Addr. 1)
PIN2 = IN2(D1) (Addr. 1)
PIN4 = IN2(D1) (Addr. 1)
PIN4 = IN3(D2) (Addr. 1)
PIN2 = IN4(D3) (Addr. 1)
PIN4 = IN4(D3) (Addr. 1)
PIN4 = IN1(D0) (Addr. 2)
PIN2 = IN2(D1) (Addr. 2)
PIN4 = IN2(D1) (Addr. 2)
PIN4 = OUT1(D0) (Addr. 2)
PIN2 = IN3(D2) (Addr. 2)
PIN4 = OUT2(D1) (Addr. 2)
PIN2 = IN4(D3) (Addr. 2)
8
Module requires two addresses
Degree of protection
Ground connection
Ambient temperature in °C
Storage temperature in °C
Status indications
• I/O display
• Display U
Aux
• AS-Interface/diagnostics display
Connection
Note 1
Note 2
8 inputs
--
Standard slaves
Y-II assignment
3RK1 200–0DQ00–0AA3
270
PIN 1 = Sensor supply L+
PIN 2 = Data input II
PIN 3 = Sensor supply L-
PIN 4 = Data input I
PIN 5 = Earth connection
--
--
--
0
1/F
PIN4 = IN1(D0) (Addr. 1)
PIN2 = IN2(D1) (Addr. 1)
PIN4 = IN2(D1) (Addr. 1)
PIN4 = IN3(D2) (Addr. 1)
PIN2 = IN4(D3) (Addr. 1)
PIN4 = IN4(D3) (Addr. 1)
PIN4 = IN1(D0) (Addr. 2)
PIN2 = IN2(D1) (Addr. 2)
PIN4 = IN2(D1) (Addr. 2)
PIN4 = IN3(D2) (Addr. 2)
PIN2 = IN4(D3) (Addr. 2)
PIN4 = IN4(D3) (Addr. 2)
8
Module requires two addresses
IP67
PIN 5 of each M12 socket is
connected with the grounding
sheet in the mounting plate
through a pin
-25 to +85
-40 to +85
Yellow LED
Green LED
Green/red LED
Using mounting plate for K60
compact module
All K60 compact modules are
supplied with high-grade steel
screws/sockets
To supply the output circuit,
an external supplementary
supply (AUX POWER)
of 20 to 30 V DC is necessary.
The supplementary supply must
comply with VDE 0106 (PELV),
Safety Class III.
8 inputs
new
--
A/B slaves
Y-II assignment
3RK2 200–0DQ00–0AA3
270
PIN 1 = Sensor supply L+
PIN 2 = Data input II
PIN 3 = Sensor supply L-
PIN 4 = Data input I
PIN 5 = Earth connection
--
--
--
0
A/E
PIN4 = IN1(D0) (Addr. 1)
PIN2 = IN2(D1) (Addr. 1)
PIN4 = IN2(D1) (Addr. 1)
PIN4 = IN3(D2) (Addr. 1)
PIN2 = IN4(D3) (Addr. 1)
PIN4 = IN4(D3) (Addr. 1)
PIN4 = IN1(D0) (Addr. 2)
PIN2 = IN2(D1) (Addr. 2)
PIN4 = IN2(D1) (Addr. 2)
PIN4 = IN3(D2) (Addr. 2)
PIN2 = IN4(D3) (Addr. 2)
PIN4 = IN4(D3) (Addr. 2)
8
Module requires two addresses