Siemens Sinumerik 802D sl Instruction Manual page 17

Hide thumbs Also See for Sinumerik 802D sl:
Table of Contents

Advertisement

CNC operator panel (PCU) interfaces
The PCU and its functions are described in the table below.
Table 2-1
Compact flash card (CF card)
slot
Power supply connection
X40
Ethernet interface
X5
USB port
X10
NC full keyboard connection
X9
RS232 COM port
X8
PROFIBUS-DP interface
X6
DRIVE-CLiQ interface
X1 and X2
Handwheel connection
X30
Digital inputs/digital outputs
X20 and X21
TB30 interface
Siemens Automation Parts
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
PCU interfaces
Interfaces
50-pin slot for CF cards, and 4 LEDs
see Chapter 4.1.1
3-pin screw-type terminal connection for connecting the 24 V load
power supply
For connecting SINUMERIK 802 D sl, please refer to Chapter 7.8
8-pin RJ45 socket connector for connection to an Industrial
Ethernet
see Chapter 4.1.2
4-pin USB host for connecting USB accessories
see Chapter 4.1.3
6-pin PS/2 socket for connecting the NC full keyboard
see Chapter 7.9
9-pin DSub connector for connecting a PG/PC
see Chapter 4.1.4
9-pin DSub socket for connection to PROFIBUSDP
see Chapter 4.1.5
8-pin RJ45 socket for connecting the SINAMICS S120 drive
see Chapter 4.1.6
12-pin screw-type male connector for connecting max. 2 hand-
wheels
see Chapter 4.1.7
12-pin screw-type male connector for connecting the digital inputs
and outputs
see Chapter 4.1.8
48-pin female connector for connecting the MCPA module
see Chapter 4.2
Description
Function
2-15

Advertisement

Table of Contents
loading