Creating a Drive Project
10.2
Operating the control panel in STARTER (with the motor rotating)
Fig. 10-33 Assuming control priority
2. Click Assume control priority to connect the control panel to the drive interface.
Note the message that is then displayed in the Control priority dialog screen. This note
is very important! (see also Fig. 10-34).
Danger
!
Be cautious when using control priority!
This function is intended exclusively for start-up and diagnosis or within the framework of
maintenance work.
Make sure that the drive is in the "OFF" status and that no ON/OFF1 command has been
issued either by the control word for sequence control or another signal source (e.g. BICO
interconnection).
Once control priority has been transferred to the PC, the BICO interconnections on bit 1 to
bit 6 of the control word are no longer active.
10-144
Click Assume control priority.
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition