Machine Problems

No Data Is Being Output to the Machine, or the Machine Will Not Operate Even Though Data Is Being Output

Is the front cover open?
Does VPanel recognize the machine?
If multiple machines are connected, is the
correct machine selected?
Is operation paused?
Is initialization or a data cancel in progress?
Is the milling data correct?
Has an error occurred?

The Computer Shuts Down when Connecting Multiple Machines

Are machines with the same ID
connected to the computer at the same
time?
66
4. Troubleshooting
If the front cover is open, the machine will not start milling
even if milling data is being received. Close all the covers,
and then press the built-in panel's operation button to start
milling.
Verify that a message other than "Offline" ("OFF" display) is
shown on VPanel.
If "Offline" (OFF) is displayed on VPanel regardless of the
machine being on, check the cable connections and similar
items.
Select the machine to output milling data to on the VPanel
screen.
Operation is paused if the PAUSE LED is lit. When the machine
is paused, milling stops and some operations are restricted.
Quickly pressing the built-in panel's operation button of the
machine will cancel the pause. Pressing and holding on the
operation button will abort milling.
Milling data received during initialization or a data cancel
will be cancelled. Make sure to output milling data after
confirming that "READY" is displayed for the machine's
operation status in the VPanel top window.
There may be problems in the milling data parameters. Check
the milling data.
The error LED will flash if an error occurs. A description of the
error is displayed in VPanel.
Connecting more than one machine with the same ID to a
computer at the same time may cause the computer to shut
down. If the computer shuts down, turn off the power of all
connected machines, and then disconnect the USB cables
from the computer.
Restart the computer, and then start VPanel. If VPanel will
not start, reinstall it. After that, configure the settings so that
no machines are assigned the same ID.