5-2 What to Do If...

Initialization is not performed or initialization fails.

Is a front cover open?
When starting the machine, close the upper and lower
front covers. For safety, initialization is not performed
when a cover remains open at startup.
Is anything caught on the spindle head or
table?
Check whether something has become caught and is
impeding initialization.
Is anything caught on the main clamp?
Perform the followings and remove any obstructions that
impede initialization.
1. Switch off the main power, and then switch on the
main power.
Never switch on the sub power.
2. Hold down
of the handy panel.
The LED lamp A lights up. Turning the handle, the main
clamp (A-axis) turns.

VPanel doesn't start correctly.

Has initialization been completed?
Before you start VPanel, first switch on the power to the
machine.
 P. 50, "Starting and quitting"
Is the computer connected?
Check whether the connector cable has come loose.
Is the driver installed correctly?
If the connection to the computer is not made in the
sequence described, the driver may fail to be installed
correctly. VPanel does not function normally when driver
is misconfigured. Check again to ensure that the connec-
tion was made using the correct procedure.
 P. 41, "Installing the Windows-based Driver"

Operations are ignored.

Is the cable connected?
Connect the cable securely.
 P. 39, "Cable Connections"
Was the machine started according to the cor-
rect procedure?
Simply switching on the power does not enable opera-
tion. Start the machine using the correct procedure.
 P. 50, "Starting and quitting"
Are front covers open?
This machine restricts some operations when a front
cover is open. Close both the upper and lower front
covers.
Is the ERROR light flashing?
The ERROR light is flashing rapidly.
An emergency stop occurred because a serious error was
detected. Resuming operation is not possible. A descrip-
tion of the error is displayed in VPanel. Switch off the main
power to quit the operation, eliminate the cause, then
redo the operation from the beginning. If the emergency
stops continue even after eliminating the cause, contact
your authorized Roland DG Corp. dealer.
 P. 50, "Starting and quitting," p. 91, "Responding to an Error
Message"
The ERROR light is flashing slowly.
Operation was paused because an error was detected. A
description of the error is displayed in VPanel. Follow the
displayed instructions to resume operation.
 P. 59, "Pausing and Resuming Operation"
Is operation paused?
When the PAUSE light is on, it means that operation
is paused. When the machine is paused, cutting stops
and some operations are restricted. Cancel the paused
state.
 P. 59, "Pausing and Resuming Operation"
Is a large amount of cutting waste present?
Clean away any cutting waste. Clean the area around the
spindle especially carefully.
 P. 84, "Care and Maintenance of the Cutting Machine"
Is the handy panel connected correctly?
When inserting, orient correctly and insert fully. Also,
before inserting or removing the connector cable for
the handy panel, switch off the power to the machine.
Making the connection while the power is on may cause
the machine to malfunction.
 P. 39, "Connecting the Handy Panel," p. 50, "Starting and
Quitting"
Is the driver installed correctly?
If the connection to the computer is not made in the
sequence described, the driver may fail to be installed
correctly. Check again to ensure that the connection was
Chapter 5 Appendix