Regulator - Sega WaveRunner Owner's Manual

Sega owner manual game waverunner
Table of Contents

Advertisement

10 - 4 REGULATOR

The compressed air (primary
side) in the air tank is governed
to preset pressures by
regulators before the air
pressure is sent to the cylinders.
Check set pressure every 2
months.
Remove Lid Left from the
Mechanism Base (refer to 11-1)
to have the Regulator Unit
appear, and check the pressure
with the Pressure Gauge
attached to each Regulator. If
the pressure within the
Compressor is insufficient, the
Regulator's Pressure Gauge will
not indicate the correct value.
When checking, first turn the
Main SW on and wait until the
Compressor operation stops.
Pressure settings given at the
time of shipment are shown in
FIG. 10. 4.
If the actual pressure is different from the set pressure, adjust it as follows:
Before proceeding the work, be sure to turn the Main SW off. However, if the pressure within
the Compressor is insufficient, adjustments can not be performed correctly. First, turn the Main
SW on, and after the Compressor operation stops, turn the SW off, and then proceed the work.
Method of adjustment
1
Pull down the Adjustment Knob of the Regulator until a click is heard.
2
Turn the Adjustment Knob to make adjustment to the preset pressure.
3
When the correct setting is established, push up the adjustment knob until a click is heard.
4
After the setting is finished, play game and check the regulator's pressure gauge once again.
6.0kgf/cm
(0.60MPa)
HIGH
LOW
HIGH
PULL DOWN
PULL DOWN
FIG. 10. 4
61
2
3.0kgf/cm
2
(0.30MPa)
LOW
www.seuservice.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Waverunner gp

Table of Contents