Overview Of Air Drive System - Sega WaveRunner Owner's Manual

Sega owner manual game waverunner
Table of Contents

Advertisement

10 - 1 OVERVIEW OF AIR DRIVE SYSTEM

This product uses the compressor. Be sure to turn off the main switch of the AC Unit and start
working after checking that the compressor motor has stopped.
1
COMPRESSOR UNIT
TANK UNIT
3
CIRCUIT PROTECTOR
1
COMPRESSOR UNIT / TANK UNIT
Compresses and stores air by causing the AC Motor to turn the Compressor.
2
FILTER / REGULATOR
Filters foreign matter consisting of fine particles, and water contents in the compression air
(primary side) stored in the COMPRESSOR UNIT and governs the compressed air to a preset
pressure (secondary side). Two Regulators are equipped with: One for high pressure and the
other for low pressure.
3
CIRCUIT PROTECTOR
Protects the AC motor for the compressor from overcurrent.
4
DRIVE BOARD (inside the Front Cabinet)
The DRIVE BOARD controls the entire Air Drive System by activating or stopping the
Compressor depending on the pressure inside the Compressor Unit, and by sending a signal to
open/close each valve in accordance with the progress of game play.
VALVE UNIT
REGULATOR
www.seuservice.com
4
DRIVE BOARD
2
FILTER
REGULATOR
POWER
FIG. 10.1 a Air Drive System Schematic
FILTER
58
VALVE
CYLINDER
VALVE
CYLINDER
VALVE
CYLINDER
COMPRESSOR
FRONT CYLINDER
REAR CYLINDER
TANK UNIT
FIG. 10.1 b Overview of air drive system