Coil Headers, Locations (continued)

Cooling Only Units

Figure 45: Chilled Water Only Unit (Coils V, S, W)
Note: This arrangement available on AVV and AVS units only.
Left Hand
Air Flow
S = Supply
R = Return
B
A
R
13-3/4"
S
(349mm)
8-1/2"
(216mm)
J
Figure 46: Direct Expansion Cooling Only Unit (Coils G)
Note: This arrangement available on AVV units only.
Cooling (Left Hand)
Air Flow
LL = Liquid Line
SL = Suction Line
D
LL
11-3/4"
SL
(299mm)
7-1/4"
(184mm)
J
C
Notes:
1.
All coils have same end supply and return connections.
2.
Steam coils have a factory installed pressure equalizing valve and a 24ʺ
(610mm) long pressure equalizing line which terminates in a 1⁄2ʺ M.P.T. fitting.
3.
Steam/hot water connections may be same end as cooling coil connections,
but they are recommended to be opposite end to facilitate piping. (Must be
opposite end when using Daikin controls.)
4.
Cooling condensate drain pan is shipped sloped down towards the cooling
coil connections but is field reversible.
5.
Electric heating coil power connections are right end only. Junction box has
1ʺ(25mm) and 2ʺ (51mm) (trade size) knockouts, 10-1⁄2ʺ (267mm) from right
end of the unit.
6.
Coil stubs are 7⁄8ʺ I.D. (female) and terminate 9ʺ (229mm) from the end of
the unit.
7.
Steam coils are 1-1⁄8ʺ female (sweat) connections and terminate 9ʺ (229mm)
from the end of the unit.
8.
DX coils (G) have O.D. sweat connections. Interconnecting tube by others.
See
Table 5
for correct tubing size.
Table 5: DX Coil (G) Connection Tubing
S07
Unit Series
in
Suction Line OD:
3/4
Liquid LIne OD:
1/4
www.DaikinApplied.com
Right Hand
B
A
R
13-3/4"
S
(349mm)
8-1/2"
(216mm)
J
Cooling (Right Hand)
Air Flow
D
LL
11-3/4"
SL
(299mm)
7-1/4"
(184mm)
J
C
S10
mm
in
mm
in
19
3/4
19
7/8
6.35
1/4
6
3/8
Condensate Drain Locations
Figure 47: Condensate Drain
Left Hand
7/8"(22 mm)
O.D. Drain
11"
(279 mm)
Figure 48: Condensate Drain and DX Coil Connections
Left Hand
5-1/4" (133 mm)
1-1/2" (38 mm)
SL
LL
TX Valve
11"
(279 mm)
Table 4: Coil Connection Dimensions For Lettered Values
Unit Depth
in .
16-5/8
3-3/4
mm
422
in .
21-7/8
mm
556
229
S13
S15
mm
in
mm
22
7/8
22
10
3/8
10
19
Right Hand
Condensate
Drain
4-3/4"
(121 mm)
11"
(279 mm)
Front View of End Compartment
(Without End Panels)
Right Hand
LL = Liquid Line
SL = Suction Line
7/8"(22 mm)
O.D. Drain
LL
4-3/4"
SL
(121 mm)
11"
(279 mm)
Front View of End Compartment
(Without End Panels)
Dimensions
A
B
C
12-1/4
4-7/8
95
311
124
9
17-1/2
10-1/8
445
257
7/8"(22 mm)
O.D. Drain
TX Valve
1-1/2" (38 mm)
5-1/4" (133 mm)
D
J
7-3/4
3
198
76
13
8-1/4
330
210
IM 817-7