Coil Headers, Locations Heating Only; Cooling Only - Daikin AVS Installation Manual

Classroom unit ventilators
Table of Contents

Advertisement

Coil Headers, Locations
Heating Only
Figure 42 - Hot Water Heating Only Unit
(Coils 65, 66, 67)
L.H. Connections
Air Flow
S = Supply
R = Return
B
A
S
13-3/4"
13-3/4"
R
(349mm)
(349mm)
8-1/2"
(216mm)
J
Table 4 - Heating Only – Coil Position/Combinations In Air Stream (one coil per position) Note: X indicates Available.
First Position in Air Stream
65
66
67
68
69
78
12
Heating Coils
65 = 1-Row Hot Water Coil
66 = 2-Row Hot Water Coil
67 = 3-Row Hot Water Coil
68 = Low Capacity Steam Coil
69 = High Capacity Steam Coil

Cooling Only

Figure 45 - Chilled Water Only Unit (Coils S, W, V)
L.H. Connections
S = Supply
Air Flow
R = Return
B
A
R
13-3/4"
S
(349mm)
8-1/2"
(216mm)
J
Table 5 - Cooling Only – Coil Position/Combinations In Air Stream (one coil per position) Note: X indicates Available.
First Position in Air Stream
Y
V
S
Heating Coils
Cooling Coils
00 = None
V = 2-Row CW Coil
S = 3-Row CW Coil
W = 4-Row CW Coil
G = Direct Expansion Coil
Y = 5-Row CW Coil
Table 6 - Dimensions
Unit
Depth
A
B
C
in
16
4
7
5
3
1
3
12
8
4
4
8
mm
422
95
311
124
17
7
in
21
9
1
10
1
8
8
2
mm
556
229
445
257
Table 7 - DX Coil (G) Connection Tubing
Unit Series
S07
Suction Line O.D. (in/mm)
3
4
Liquid LIne O.D. (in/mm)
1
4
Page 18 of 60
Figure 43 - Steam Heating Only Unit
(Coils 68, 69, 78, 79)
L.H. Connections
R.H. Connections
Air Flow
B
H
S
A
R
8-1/2"
(216mm)
J
Note: For opposite end drain steam coils (code 78,79) Return (R)
is 7
of unit.
Second Position in Air Stream
79
Z
13
Z
78 = Opposite End Drain Low Capacity Steam Coil
79 = Opposite End Drain High Capacity Steam Coil
12 = Low Electric Heat Coil
13 = High Electric Heat Coil
R.H. Connections
Air Flow
B
A
R
13-3/4"
S
(349mm)
8-1/2"
(216mm)
J
Second Position in Air Stream
W
00
G
00
Dimensions
D
E
F
G
H
7
7
3
5
1
3
1
10
2
2
4
8
8
4
8
198
41
257
70
73
143
6
8
8
7
13
15
3
1
10
8
8
8
330
175
391
203
206
276
S10
S13
S15
7
7
3
19
19
22
4
8
8
6.35
6
1
3
10
3
4
8
8
Air Flow
S = Supply
K
R = Return
S
R
16-1/8"
16-1/8"
(410mm)
(410mm)
11"
11"
(279mm)
(279mm)
J
"(184mm) from bottom of unit and H - 2"(51mm) from back
1
4
Face and Bypass
AVS
X
Cooling Coils
Z = None
Figure 46 - Direct Expansion Cooling Only Unit (Coil G)
L.H. Connections
Air Flow
B
D
LL
J
Face and Bypass
AVS
X
Notes:
1. All coils have same end supply and return connections.
2. Steam coils have a factory installed pressure equalizing valve and
a 24" (610mm) long pressure equalizing line which terminates
in a
3. Steam/hot water connections may be same end as cooling
coil connections, but they are recommended to be opposite
end to facilitate piping. (Must be opposite end when using AAF
controls.)
I
J
K
/
4. Cooling condensate drain pan is shipped sloped down towards
5
5
3
5
8
the cooling coil connections but is field reversible.
76
127
5. Electric heating coil power connections are right end only.
8
7
1
10
1
8
4
4
Junction box has 1"(25mm) and 2" (51mm) (trade size)
210
260
knockouts, 10
6. For limitations with coil combinations see tables 4, 5, 8 and 9.
7. Coil stubs are
end of the unit.
8. Steam coils are 1
9" (229mm) from the end of the unit.
22
9. DX coils (G) have O.D. sweat connections. Interconnecting tube
10
by others. See table 7 for correct tubing size.
Figure 44- Electric Heating Only Unit
(Coils 12, 13)
R.H. Connections
Electric Heating
Air Flow
K
H
S
R
J
Valve
AVV
AVV Elect..
X
X
SL
11-3/4"
11-3/4"
(299mm)
(299mm)
13-3/4"
(349mm)
(184mm)
Valve
AVV
X
X
" M.P.T. fitting.
1
2
" (267mm) from right end of the unit.
1
2
" I.D. (female) and terminate 9" (229mm) from the
7
8
" female (sweat) connections and terminate
1
8
R.H. Connections
Air Flow
Only
Junction Box
14"
(356mm)
J
L
R.H. Connections
Air Flow
D
LL
SL
7-1/4"
J
C
IM 817-4