131; User Provisioning Fortr-069 - Technicolor CGA4131 Operation Manual

Business gateway
Table of Contents

Advertisement

14 TR-069
TR-069(Technical Report 069) is a method to remotely and securely manage CPE
configuration from a central Auto Configuration Server or ACS. The following figure shows
a simple and typical deployment layout. The ACS simply needs to be network accessible by
the eRouter interface.
Figure 14.1
To configure TR-069, rdkbTR069ClientMode should be set to enable (1) and
rdkbTR069ClientAcsUrl should point to the ACS server (e.g. http://myacs.acs.lab.sa).
rdkbTR069ClientAllowDocsisConfig must be set to enable (1) to reconfigure any TR-069
parameters including the ACS URL above.
During
the
initial
device
check,
the
server
will
populate
the
rdkbTR069ClientAcsControlPanelUrl,
rdkbTR069ClientCrUsername
andrdkbTR069ClientCrPassword fields.
The client device identifier can also be set as either MAC or serial number when registering
to the TR-069 server. This affects the Internet Gateway Device, Device Info, Serial Number
and Parameter in the TR-069 object model.

14.1 User provisioning forTR-069

The user does not configure TR-069, as it is for remote management by the service operator
from the auto configuration server.
3/6/2018
Proprietary and Confidential - Technicolor

131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents