Figure 3-7: – Inline Model Mounted to an Optional Bracket
3. Loosen the set screw on the outside neck of the Transmitter one (1) full turn.
4.
Rotate the Electronics housing a maximum of 180
you require, and tighten the set screw 8.9 to 9.7 lb-in (1.40 to 1.68 Nm), using a 4mm metric
socket head wrench. See
EXAMPLE: Rotating the Electronics Housing.
The mounting position of absolute pressure models STAW822, STAW82L, or a draft range
model STDW810 is critical as the transmitter spans become smaller.
A maximum zero shift of 2.5 mmHg for an Absolute transmitter or 1.5 inches of water (inH
for a Draft Range transmitter can result from a mounting position that is rotated 90
18
Figure 3-8.

Figure 3-8: Rotating the Electronic Housing

SmartLine Wireless User's Manual