Honeywell SmartLine User Manual page 105

Table of Contents

Advertisement

Wireless Pressure continued ..
Name
Description
SENSOR_DEVREV
Device Revision
SENSOR_BUILD
Software Version
MAINTENANCE_ALERT
Maintenance Alert
MAINTENANCE_ALERT.ALERT_DISABLE
Enable or Disable the Alert
MAINTENANCE_ALERT.ALERT_PRIORITY
Priority set for the Alert
OUT_OF_SPEC_ALERT
Out of Specification Alert
OUT_OF_SPEC_ALERT.ALERT_DISABLE
Enable or Disable the Alert
Priority set for the Alert
OUT_OF_SPEC_ALERT.ALERT_PRIORITY
FUNCTION_CHECK_ALERT
Function Check Alert
FUNCTION_CHECK_ALERT.ALERT_DISABLE
Enable or Disable the Alert
FUNCTION_CHECK_ALERT.ALERT_PRIORITY
Priority set for the Alert
FAILURE_STATUS_ALERT
Failure Status Alert
FAILURE_STATUS_ALERT.ALERT_DISABLE
Enable or Disable the Alert
FAILURE_STATUS_ALERT.ALERT_PRIORITY
Priority set for the Alert
Power source
POWER_SOURCE
V_POWER
Power voltage
EUI_64
Field device radio EUI64 unique identifier.
DL_ALIAS_16_BIT
Field device radio short address.
NETWORK_ADDRESS_128_BIT
Field device radio IP6 address.
DEVICE_ROLE_CAPABILITY
Field device radio role capability.
VENDOR_ID
Field device radio vendor ID.
MODEL_ID
Field device radio model ID.
TAG_NAME
Field device tag name.
SERIAL_NUMBER
Field device radio serial number.
Field device power supply status.
POWER_SUPPLY_STATUS
JOIN_COMMAND
Field device radio join command.
RESTART_COUNT
Field device radio restart counter.
UPTIME
Field device radio uptime.
SOFTWARE_REVISION
Field device radio revision.
DROP_OFF_COUNT
Field device radio network drop off counter.
JOIN_ATTEMPT_COUNT
Field device radio network join attempt counter.
Field device radio reset counters command.
RESET_COUNTERS
ROUTING_ASSIGNMENT
Field device radio network routing assignment.
Revision 2
Data Type
Data Size Access
Class
Enum Value
Uint16
2 Read Only
Static
Uint16
2 Read Only
Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
Uint8
1 Read Only
Dynamic
1 - Battery Module
2 - 24V External Power Module
Float
4 Read Only
Dynamic
OctetString
0 Read Only
Constant
Uint16
2 Read Only
Static
OctetString
0 Read Only
Static
Uint16
2 Read Only
Constant
128 - Provisioning Device
64 - System Time Source
32 - Security Manager
16 - System Manager
8 - Gateway
4 - Access Point
2 - Routing Device
1 - I/O Device
VisibleString
16 Read Only
Constant
VisibleString
16 Read Only
Constant
VisibleString
16 Read/Write Static
VisibleString
16 Read Only
Constant
Uint8
1 Read Only
Dynamic
0 - Line Powered
1 - Battery
2 - Battery
3 - Battery
Uint8
1 Read/Write Static
0 - None
2 - Warm Restart
3 - Restart as Provisioned
Uint16
2 Read Only
Static
Uint32
4 Read Only
Dynamic
VisibleString
16 Read Only
Constant
Uint16
2 Read Only
Static
Uint16
2 Read Only
Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
0 - Routing Disabled
1 - Routing Enabled
2 - Not Applicable
SmartLine Wireles User's Manual
Enum Description
Device is powered by internal battery
Device is powered using 24V external
power
Provisioning Device
System Time Source
Security Manager
System Manager
Gateway
Access Point
Routing Device
I/O Device
Line Powered
High
Battery powered
greater than 75% remaining
Medium
Battery powered
between 25% to 75% remaining
Low
Battery powered
less than 25% remaining
None
Warm Restart
Restart as Provisioned
Routing Disabled
Routing Enabled
Not Applicable
91