Transistor Input Units
Wiring
Dimensions
65
4
I/O power
supply
NPN output
3-wire sensor
(photoelectric or
proximity sensor)
Note
1. V terminals and G terminals are respectively connected internally. When the
I/O power is being supplied, the power can be supplied to the input devices
from the V terminals and G terminals. Current supplied in this way, however,
must be less than 1 A.
2. Make sure there are no more than 12 inputs turned ON at the same time.
140
Note The vertical center of the Unit is 4.9 mm lower than the center of the DIN track.
The Unit therefore extends downward 41.4 mm (including the mounting hook)
from the DIN track center.
2-wire sensor
(limit switch)
Wire colors in parentheses are the previous JIS colors
for photoelectric and proximity sensors.
Section
NPN output 3-wire
sensor
(photoelectric or
proximity sensor)
Approx. 89
80
60
35
(Unit: mm)