Real time monitor
Refer to page 134 for details of the monitor description.
Register
Rotation speed/Machine speed/
40201
Output frequency
Output current
40202
Output voltage
40203
Rotation speed setting/Machine
40205
speed/Frequency setting
40208
Converter output voltage
40209
Regenerative brake duty
Electronic thermal relay function
40210
load factor
40211
Output current peak value
40212
Converter output voltage peak value
40214
Output power
40215
Input terminal status
40216
Output terminal status
40220
Cumulative energization time
40223
Actual operation time
Use Pr. 37 to set 1 increments, and use Pr. 144 to set 0.01Hz increments. (Refer to page 132 for Pr. 37 and Pr. 144.)
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
—
—
—
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
—
—
—
The monitored values are retained even if a drive unit fault occurs. Resetting will clear the retained values.
Description
Unit
1/1/0.01Hz
0.01A
0.1V
1/1/0.01Hz
0.1V
0.1%
0.1%
0.01A
0.1V
0.01kW
—
—
1h
1h
—
—
—
—
—
—
—
—
Communication operation and setting
Register
40224
Motor load factor
40225
Cumulative power
40252
PID set point
40253
PID measured value
40254
PID deviation
40261
Motor thermal load factor
40262
Drive unit thermal load factor
40263
Cumulative power 2
40264
PTC thermistor resistance
32-bit cumulative power
40277
(lower 16-bit)
32-bit cumulative power
40278
(upper 16-bit)
32-bit cumulative power
40279
(lower 16-bit)
32-bit cumulative power
40280
(upper 16-bit)
—
—
RH
RM
—
—
—
ABC
Description
Unit
0.1%
1kWh
0.1%
0.1%
0.1%
0.1%
0.1%
0.01kWh
0.01k
1kWh
1kWh
0.01kWh
0.01kWh
RL
—
—
STR
—
—
—
—
b0
STF
b0
RUN
4
213