Communication operation and setting
[Drive unit status monitor]
Instruction
Item
Code
Length
Drive unit
status
H7A
8 bits
monitor
Drive unit
status
H79
16 bits
monitor
(expansion)
 The signal is the initial setting. The description changes depending on the Pr. 190, Pr. 192 (output terminal function selection).
[Multi command (HF0)]
Sending data format from computer to drive unit
Format
1
2
3
Drive unit
A3
ENQ
station
number
Reply data format from drive unit to computer (No data error detected)
Format
1
2
3
Drive unit
C1
STX
station
number

Specify the data type of sending data (from computer to drive unit).

Specify the data type of reply data (from drive unit to computer).

Combination of data 1 and data 2 for sending
Data Type
0
1

Combination of data 1 and data 2 for reply
Data Type
Drive unit status
0
monitor (extended)
Drive unit status
1
monitor (extended)

Error code for sending data 1 is set in error code 1, and error code for sending data 2 is set in error code 2.
Mode error (HA), instruction code error (HB), data range error (HC) or no error (HF) is replied. (Refer to page 195 for more details of the error codes.)
202
Bit
Description
b0: RUN (drive unit running (Variable)) 
b1: Forward rotation (Fixed)
b2: Reverse rotation (Fixed)
b3: up-to-speed (Fixed)
b4: overload (Fixed)
b5: —
b6: speed detection(Fixed)
b7: ABC (fault (Variable))
b0: RUN (drive unit running (Variable)) 
b1: During forward rotation (Fixed)
b2: During reverse rotation (Fixed)
b3: up-to-speed (Fixed)
b4: overload (Fixed)
b5: —
b6: speed detection(Fixed)
b7: ABC (fault (Variable))
b8 to b14: —
b15: Fault occurrence
4
5
6
7
Instruction
Send
Waiting
code
data
time
(HF0)
type
4
5
6
7
Send
Receive
Error
Error
data
data
code 1
code 2


type
type
Data 1
Data 2
Run command
Set speed (RAM)
(extended)
Run command
Set speed (RAM,
(extended)
EEPROM)
Data 1
Data 2
Rotation speed
(Output frequency)
Special monitor
[Example 1] H0003... During forward rotation
b15
0
0
[Example 2] H8080... Stop at fault occurrence
b15
1
0
Number of Characters
8
9
10
11
12
Receive
data
Data1
type
Number of Characters
8
9
10
11
12
Data1
Run command (expansion) is same as instruction code HF9
(Refer to page 201.)
The unit of set speed (frequency) is always by four digits, even
when "0.01 to 9998" is set in Pr. 37 and "01" is set in instruction
code HFF.
Drive unit status monitor (expansion) is same as instruction code
H79 (Refer to page 202.)
Rotation speed (frequency) monitor is in 1 increments. (Numbers
after the decimal point are rounded.)
Replies the monitor item specified in instruction code HF3 for
special monitor.(Refer to page 200.)
Example
[Example 1] H03... During forward rotation
b7
b0
0
0
0
0
0
0
1
1
[Example 2] H80... Stop at fault occurrence
b7
b0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
13
14
15
16
Data2

13
14
15
16
Data2
ETX

Remarks
Remarks
b0
0
0
0
0
1
1
b0
0
0
0
0
0
0
17
18
19
Sum
CR/LF
check
17
18
19
Sum
CR/LF
check