Minimum Motor Rotation Speed (Pr. 13) - Mitsubishi Electric FR-D720-0.2K-G Instruction Manual

S-pm geared motor drive unit fr-d700-g series
Table of Contents

Advertisement

Setting of acceleration/deceleration time and acceleration/ deceleration pattern
4.8.2

Minimum motor rotation speed (Pr. 13)

Set the speed where the motor starts running.
Set the deadband in the low-speed range to eliminate noise and offset deviation when setting a speed with analog input.
Parameter
Name
Number
13
Starting speed
The above parameters can be set when Pr. 160 Extended function display selection = "0". (Refer to page 161.)

The value left of the slash is for the 2.2K drive unit or lower. The one right of the slash is for the 3.7K drive unit.

If a value exceeding the upper speed limit of the motor is set, the actual operation will be limited at the maximum rotation speed. The setting range is for the
S-PM motor. The maximum setting value differs depending on the number of poles of the applied motor.
Rotation speed
(r/min)
1800/1200
Set
speed
Setting
range
Pr. 13
0
*
Forward rotation
ON
* Output from 1r/min
Note that when Pr. 13 is set to any value lower than Pr. 2 Minimum setting, simply turning ON the start signal
will run the motor at the preset speed even if the command speed is not input.
Parameters referred to
Pr. 2 Minimum setting
Pr. 7 Acceleration time
Initial Value
15r/min
 The speed where the PM motor starts running can be set.
 While the speed command is less than the Pr. 13 Starting speed
setting, the PM motor is stopped.
Rotation speed
When the speed command reaches the Pr. 13 setting or higher,
the PM motor accelerates according to the Pr. 7 Acceleration time
setting.
Time
CAUTION
Refer to page 87.
Refer to page 97.
Setting Range
0 to 1800r/min /
The speed where the motor starts
0 to 1200
r/min

running.
Description
99