Electrical Requirements
Wolf downdraft ventilation systems
require a separate, grounded 120V,
60 Hz power supply. The service
should have its own 15 amp circuit
breaker and a grounded 3-prong
receptacle should be located within
the reach of the 2' (.6 m) power
cord. The specific location of the
outlet is not critical, as long as it is
within reach of the power cord that is
located mid-way, top and bottom on
the right side of the downdraft.
IMPORTANT NOTE: If the 30" (762)
downdraft is being installed in a 30"
(762) wide cabinet, or the 36" (914)
downdraft in a 36" (914) wide
cabinet, the outlet cannot be located
on the back wall of the cabinet. The
outlet may be placed in adjacent
cabinetry. Locate electrical within the
shaded area shown in the illustration.
IMPORTANT NOTE: A ground fault
circuit interrupter (GFCI) is not
recommended and may cause inter-
ruption of operation.
You must follow all National Electrical
Code regulations. In addition, be
aware of local codes and ordinances
when installing your service.
Discharge Location
Wolf downdraft systems have an
adjustable discharge that will allow
you to negotiate ducting around floor
joists and other obstacles. Three
different discharge locations are avail-
able with side to side adjustment for
accurate alignment of ductwork.
Refer to the illustration for discharge
location and adjustment.
Dimensions in parentheses are in millimeters unless otherwise specified.
V
E N T I L A T I O N
4"
min (102)
1
E
3
/
"
2
(89)
10"
(254)
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
24"
min
(610)
Electrical placement for 30" (762) and 36" (914) downdrafts.
CENTERLINE OF COUNTERTOP CUTOUT
1 /8
22
"
(562)
INTERNAL BLOWER
19"
(483)
REMOTE BLOWER
CENTERLINE OF COUNTERTOP CUTOUT
ADJUSTMENT:
5"
MAX (127)
REMOTE BLOWER
Discharge location and adjustment for downdraft ventilation system.
C L
RIGHT
DISCHARGE
LOCATION
1 /2
5
"
(140)
INTERNAL BLOWER
1 /4
4
"
(108)
LEFT
REMOTE BLOWER
DISCHARGE
LOCATION
C L
1 /2
5
"
(140)
INTERNAL BLOWER
1 /4
4
"
(108)
BOTTOM
REMOTE BLOWER
DISCHARGE
LOCATION
NOTE: Measurements are to centerline of duct cutouts
4"
min (102)
1
3
/
"
E
2
(89)
10"
(254)
30"
min (762)
FOR MODEL DD30
36"
min (914)
FOR MODEL DD36
3 /8
16
"
(416)
INTERNAL BLOWER
1 /2
21
"
(546)
REMOTE BLOWER
DISCHARGE CUTOUT
DIMENSIONS:
1 /4
1 /2
10
"
x 3
"
(260)
(89)
INTERNAL BLOWER
1 /4
1 /2
14
"
x 3
"
(362)
(89)
REMOTE BLOWER
ADJUSTMENT:
1"
- 7"
(25)
(178)
INTERNAL BLOWER
1 /2
2
"
MAX (165)
REMOTE BLOWER
67