Wolf SO30U Design Manual page 27

Built-in ovens, warming drawers, microwave ovens, cooktops, dual fuel ranges, rangetops, gas bbq grills, cooktop ventilation
Hide thumbs Also See for SO30U:
Table of Contents

Advertisement

W
U
O L F
N F R A M E D
3 0 "
U N F R A M E D
( 7 6 2 )
E L E C T R I C C O O K T O P
Wolf recommends using 33" (838)
cabinets with the 30" (762) cooktop.
The Wolf 30" (762) unframed electric
cooktop can be mounted flush with
the top of the countertop or as a
frameless installation sitting on top of
the countertop surface. In either
installation the cooktop cut-out
dimensions are the same. If it is to be
mounted flush with the countertop,
you will need to provide a recessed
area surrounding the cooktop cut-
out. Refer to the countertop cut-out
dimensions in the illustration.
IMPORTANT NOTE: If the cooktop is
to be mounted flush with the coun-
tertop, fabrication of the recessed
area must take place before the final
countertop installation. A template
for the countertop cut-out will be
provided with the cooktop.
A Wolf 30" (762) single oven may be
installed below the 30" (762)
unframed electric cooktop. Refer to
the illustration for specifics on cut-out
dimensions and electrical placement.
When an oven is installed below the
cooktop, it is recommended that
the electrical supply be placed in the
adjacent base cabinet within the
shaded area shown in the illustration.
The top right area in the oven cavity
is available, but will make installation
difficult. The bottom cabinet support
must be able to support 250 lbs
(113 kg).
E
C
L E C T R I C
O O K T O P S
The Wolf 30" (762) unframed
electric cooktop requires a separate,
grounded 3-wire 240V, 40 amp
service with its own circuit breaker.
It has a 4' (1.2 m) flexible 3-wire
conduit for connection at the electri-
cal supply.
13"
(330)
SEE COUNTERTOP
CUT-OUT BELOW
1
E
3
/
"
2
(89)
4"
min
(102)
10"
(254)
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
24"
min
(610)
* Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to cooking surface.
** Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above cooking surface.
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
COUNTERTOP
PROFILE
7
/
"
8
(22) max
5
/
"
( 24 )
16
* Minimum dimension, but may be exceeded by up to 1/8" (3).
Countertop cut-out dimensions and electrical placement for 30" (762) unframed
electric cooktop above 30" (762) single oven.
At 240 V this cooktop is rated at 6.8
Kw and at 208 V rated at 5.2 Kw with
a minimum 30 amp service.
WARNING
This cooktop is intended for
indoor use.
24"
30"*
OR
(610 or 762)
18"
TO COOKING
(457)
SURFACE
2"**
(51)
36"
(914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
4
FLUSH MOUNT INSTALLATION ONLY
5
1
/
"
16
(33)
RADIUS
1
21
/
"*
8
(537)
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
9
1
/
"
16
(40)
30"
(762)
33"
(838)
RECOMMENDED
CABINET WIDTH
18"
(457)
SEE COUNTERTOP
CUT-OUT BELOW
2"**
(51)
4"
(102)
1
3
/
"
E
2
(89)
4"
min
10"
(102)
(254)
30-INCH OVEN
ROUGH OPENING
3
/
"
4
min
(121)
1
30
/
"*
( 765 )
8
RECESSED AREA FOR
3
28
/
"
8
(721) COOKTOP
CUT-OUT WIDTH
7
/
"
16
(11) RADIUS
3
19
/
"
8
(492)
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
7
2
/
"
16
(62)
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents