W
G
C
O L F
A S
P L A N N I N G
I N F O R M A T I O N
Wolf offers three sizes of gas cooktops
to choose from to address your
clients' needs. The 30" (762) and 36"
(914) cooktops are available in classic
and platinum stainless steel finish.
The 15" (381) cooktop module comes
in classic stainless steel only.
Space Requirements
The illustrations of the three different
size cooktops give you overall dimen-
sions, while the finished cut-out
dimensions you need to incorporate
into your plans are shown in the
illustrations on the following pages.
A Wolf single 30" (762) or 36" (914)
built-in oven may be installed below
these cooktops. Refer to the illustra-
tions on the following pages for
specifics on cut-out dimensions and
placement of electrical. Also, be
aware of the depth of the cooktop
when planning for this installation.
Wolf gas cooktops are designed and
agency approved for installation with
Wolf built-in ovens only. The cooktop
nominal width should match the
built-in oven nominal width.
Refer to the installation instructions
shipped with each Wolf product for
detailed specifications.
These cooktops can accommodate
the Wolf downdraft system, a Wolf
chimney or Pro Series hood. When
installing a ventilation hood, refer to
the specific requirements of the hood
for the minimum dimension to
cooking surface. Refer to pages 60-82
for ventilation specifics.
Dimensions in parentheses are in millimeters unless otherwise specified.
O O K T O P S
Electrical and Gas Requirements
The electric ignition system is a safe,
convenient and reliable manner to
provide ignition for the burners.
However, you need to make provi-
sions for a separate 120V, 60 Hz
power supply. The service should have
its own 15 amp circuit breaker and a
grounded 3-prong receptacle should
be located within the reach of the
6' (1.8 m) power cord. Refer to the
illustrations on the following pages.
IMPORTANT NOTE: A ground fault
circuit interrupter (GFCI) is not recom-
mended and may cause interruption
of operation.
Wolf gas cooktops are designed to
operate on natural gas at 5" (127) WC
(water column) pressure or LP gas at
10" (254) WC pressure. They are
supplied with a 1/2" NPT male gas
connection at the right rear corner on
the bottom of the cooktop. The male
connector exits the unit straight down
and you are supplied with a regulator
with two female connectors.
Wolf gas cooktops using natural gas
function up to an altitude of 8000'
(2438 m) without any adjustment.
Natural gas installations from 8000'
(2438 m) to 10,000' (3048 m) need
the high altitude conversion kit. LP
gas installations will operate up to
10,000' (3048 m) without adjustment.
You must follow all National Electrical
Code and gas regulations. In addition,
be aware of local codes and ordi-
nances when installing your services.
21"
(533)
OVERALL
DEPTH
15"
(381)
OVERALL WIDTH
4"
(102)
Model CT15G – Overall Dimensions
30"
(762)
OVERALL WIDTH
Model CT30G – Overall Dimensions
36"
(914)
OVERALL WIDTH
Model CT36G – Overall Dimensions
21"
(533)
OVERALL
DEPTH
4"
(102)
21"
(533)
OVERALL
DEPTH
4"
(102)
31