Wolf SO30U Design Manual page 66

Built-in ovens, warming drawers, microwave ovens, cooktops, dual fuel ranges, rangetops, gas bbq grills, cooktop ventilation
Hide thumbs Also See for SO30U:
Table of Contents

Advertisement

W
C
O L F
O O K T O P
P L A N N I N G
I N F O R M A T I O N
The downdraft ventilation system
should be at least as wide as the
cooking surface you are designing
into the home.
The 30" (762) downdraft will fit most
30" (762) wide cabinets and the 36"
(914) downdraft will fit most 36"
(914) wide cabinets. Cabinet backs
may need to be removed. It is recom-
mended that oversized cabinets be
used for easier installation.
IMPORTANT NOTE: To incorporate
a downdraft system and a Wolf
cooktop, you must allow for a
minimum 25-1/8" (638) flat counter
space from front to back. A counter-
top with a raised lip and/or back-
splash may not allow enough space
for proper installation. 2-3/8" (60) of
flat countertop is required behind the
cooktop and 1-3/4" (44) is necessary
between the back edge of the
cooktop and inside of cabinet back.
Follow dimensions given in the illus-
tration.
If a downdraft ventilation system is
installed in combination with two
integrated cooktops, an integrated
cooktop support for downdraft
ventilation (ISUPPORT) is required.
IMPORTANT NOTE: This appliance
must be used with a Wolf approved
control module and top cover. The
remote mounted control module is
sold as a sales accessory.
Contact your Wolf dealer for informa-
tion on optional accessories.
66
V
E N T I L A T I O N
The installation of the control module
must be within 10' (3 m) of the
downdraft assembly and a minimum
of 4" (102) from the outer edge of
cooktop element or burner. You will
be required to drill three holes and
connect the two units by the provided
wire.
1
OF COOKTOP
TO INSIDE OF
CABINET BACK*
COUNTERTOP
TO BOTTOM OF
COUNTERTOP
Installation dimensions for 30" (762) and 36" (914) downdrafts.
1 /8
25
"
min (638)
3 /4
"
min (45)
OF FLAT COUNTERTOP*
BACK EDGE
5 /8
"
(16)
1 /4
19
"
(489)
COOKTOP CUT-OUT
DEPTH
.344"
3 /8
2
"
(67)
1 /8
2
"
(54)
1 /4
3
"
(83)
5 /16
29
"
(745)
5 /8
3
"
AIR BOX
(92)
5"
18"
(127)
(457)
1 /8
7
"
(181)
24"
min (610)
CABINET DEPTH
*AREAS OF POTENTIAL INTERFERENCE
7 /8
26
"
FOR 30" DOWNDRAFT
7 /8
32
"
1 /8
25
"
FOR 36" DOWNDRAFT
min
(638)
FLAT
COOKTOP CUT-OUT
WIDTH
SPACE
COUNTERTOP TOP VIEW
Refer to the installation instructions
provided each Wolf ventilation product
for detailed specifications. These
instructions can also be found on the
Wolf website.
1 /2
2
"
min
(64)
WITH NO
RAISED LIP*
11 /16
7
"
(197)
36"
(914)
3 /4
2
"
(70)
(683)
(835)
1 /4
19
"
(489)
1 /2
2
"
min
(64)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents