Blower Considerations
Wolf chimney wall and island hoods
are shipped without the blower
assembly. Internal or remote blower
assemblies are available. For chimney
wall hoods, the remote blower can be
mounted on the roof or an exterior
wall. For island hoods, the remote
blower will be mounted on the roof.
The blower will vary in size and is
dictated by the cooking surface and
the distance to the exterior of the
home. Blower options also vary with
the volume of air that needs to be
moved and the length of the duct
run. A straight, short duct run with a
limited number of elbows and transi-
tions will allow the ventilation hood
to perform most efficiently.
A remote mounted blower will
minimize the amount of blower
noise, but will not eliminate the noise
completely.
IMPORTANT NOTE: Install this venti-
lation hood only with a Wolf blower.
Refer to the cooktop ventilation
charts on pages 79-80 for recommen-
dations and blower options.
Ducting Considerations
IMPORTANT NOTE: All Wolf ventila-
tion hoods must be vented to the
outside. Use only metal ductwork.
Local building codes may require the
use of make-up air. Consult your local
HVAC professional for specific require-
ments in your area.
Wolf chimney wall hoods have an 8"
(203) round vertical discharge.
Ducting for chimney wall hoods can
run through the roof or an external
wall as shown in the illustration.
Dimensions in parentheses are in millimeters unless otherwise specified.
V
E N T I L A T I O N
ROOF CAP OR REMOTE BLOWER
8" (203) ROUND DUCT
CHIMNEY FLUE EXTENSION
TELESCOPIC CHIMNEY FLUE
8" (203) ROUND ELBOW
8" (203) ROUND DUCT
7
6
/
"
8
(175 - 235)
24"
(610 - 762)
COOKING SURFACE
TO BOTTOM OF
VENTILATION HOOD
Ducting considerations for 30" (762) and 36" (914) chimney wall hoods.
CHIMNEY
1
9
/
"
OR
4
WALL HOOD
21"
(535)
30"
TO
DUCTWORK INSTALLATION
THROUGH ROOF
WALL CAP
OR REMOTE BLOWER
DUCTWORK INSTALLATION
THROUGH WALL
8" (203) ROUND
VERTICAL DISCHARGE
63