IMPORTANT NOTE: Caution must be
used in planning the proper installa-
tion of the Wolf gas rangetop to
avoid any fires or damage to adjacent
cabinetry or kitchen equipment.
Please follow the minimum clearances
established in the finished rough
opening dimensions as shown in the
illustration.
All Wolf gas rangetops come in the
classic stainless steel finish and are
shipped with the distinctive red
control knobs. Contact your Wolf
dealer for optional black knobs
available at no cost.
It is recommended that you use a
Wolf Pro Series wall or island ventila-
tion hood with the Wolf gas
rangetop. Refer to pages 69-78 for
Pro Series ventilation specifics.
Space Requirements
The finished rough opening dimen-
sions you need to incorporate into
your plans are noted on the following
page. Also refer to the chart below.
We have minimized the information
contained in the illustrations, concen-
trating on the critical information you
must plan into your installation.
Refer to the installation instructions
shipped with each Wolf product for
detailed specifications.
Installation Dimensions
Overall Width of Gas Rangetop – width may vary to + _
A
B
Finished Rough Opening Width
C
Location of Electrical and Gas Supply
NOTE: Dimensions correspond to the illustrations on the following page. Dimensions in parentheses are in millimeters.
54
A N G E T O P S
Electrical and Gas Requirements
The Wolf gas rangetop requires a
110/120V electric supply to operate
the electronic ignition system. The 6'
(1.8 m) power supply cord provided
with the rangetop is equipped with a
3-prong, grounded plug for protec-
tion against shock hazard. The service
should have its own 15 amp circuit
breaker. Locate electrical within the
shaded area shown in the illustration.
IMPORTANT NOTE: A ground fault
circuit interrupter (GFCI) is not
recommended and may cause inter-
ruption of operation.
Wolf gas rangetops are designed to
operate on natural gas at 5" (127)
WC (water column) pressure or LP
gas at 10" (254) WC pressure. The
maximum gas supply pressure to the
regulator should never exceed 14"
(356) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a 1/2"
(13) I.D. commercial type flex hose;
this is the minimum size that may be
used. All plumbing to the flex hose
MUST be 3/4" (19) minimum I.D.
pipe.
The Wolf gas rangetop functions up
to 6000' (1828 m) in altitude without
any adjustment. If the installation is
above 6000' (1828 m), contact your
Wolf dealer.
1
36" (914)
Gas Rangetop
/
" (3)
8
36
IMPORTANT NOTE: A separate
external gas shut-off valve must be
located near the rangetop in an
accessible location.
You must follow all National Electrical
Code and gas regulations. In addition,
be aware of local codes and ordi-
nances when installing your services.
36" (914)
1
/
" (921)
4
8" (203)
48" (1219)
Gas Rangetop
48" (1219)
1
48
/
" (1226)
4
16" (406)