Manufactured Mobile Home Additional Requirements; Locating Your Gas Fireplace; Unit Specifi Cations; Heatwave Optional Duct System Kit - Regency P48-2 Owners & Installation Manual

Regency gas fireplace owners & installation manual
Hide thumbs Also See for P48-2:
Table of Contents

Advertisement

6) Install standard and optional features. Refer
to the following sections:
a)
Brick Panels Installation
b)
Log Set Installation
c)
Standard Flush Door
d)
Flush Louvers
e)
Flush Trim
f)
Bay Door
g)
Bay Trim
h)
Bay Louvers
i)
Finishing trim
j)
Double Screen Door
k)
Remote Control
l)
Wall Switch
m)
Wall Thermostat
n)
Installing the Fan
11) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 51,000 (NG)
Btu/h, 48,000 (LP) Btu/h) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided. See "Wiring Diagram"
section.
®
Regency
P48-2 Zero Clearance Direct Vent Gas Fireplace
UNIT SPECIFICATIONS
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for
servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The P48-2 Direct Vent Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into
Wall/Alcove
D)
Corner
INSTALLATION
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P48-2 Direct Vent Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on this page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For vent terminations see "Exterior
Ve n t Te r m i n a t i o n L o c a t i o n s "
section.
HEATWAVE
OPTIONAL
DUCT SYSTEM KIT
The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.
Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.
OPTIONAL
HEAT RELEASE KIT
The Heat Release Kit expels warm air from
the fi replace to the outside of the building,
allowing the fi replace to be operated with less
heat entering the room. The kit may be used on
either the left or right side.
Diagram 1
A hearth is not mandatory, but is recommended
for aesthetics and for added safety.
#946-556
#946-570

HEARTH

7