These venting systems, in combination with the P48-2 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.
®
Regency
Direct Vent (Flex) System
Termination Kit (Part# 946-618) includes all
the parts needed to install the P48-2 with a
maximum run of 4 feet.
1) 8" dia. fl exible liner (6 ft. length)
2) 5" dia. fl exible liner (6 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap XL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
If longer runs are needed, the Regency
Vent system (Flex) Part# 946-616 includes all
the parts needed to install the P48-2 with a
maximum 10' run.
1) 8" dia. fl exible liner (10 ft. length)
2) 5" dia. fl exible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap XL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency
3) If you are installing the P48-2 into a Regency
include the mantel base in your calculations and to maintain the 2-1/2" clearance to the underside of the mantel top.
®
Regency
P48-2 Zero Clearance Direct Vent Gas Fireplace
VENTING ARRANGEMENTS
HORIZONTAL TERMINATION
®
Regency
Direct Vent System (Flex)
®
Direct
®
may be used for Flex installations.
®
Mantel Kit, use the minimum horizontal vent height (centre-line of 43"). Remember to
INSTALLATION