Door Glass; Glass Replacement; Bay Glass Replacement; Installing Valve - Regency P48-2 Owners & Installation Manual

Regency gas fireplace owners & installation manual
Hide thumbs Also See for P48-2:
Table of Contents

Advertisement

MAINTENANCE

DOOR GLASS

Your Regency
®
fi replace is supplied with high
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this fi replace without the
glass front or with a cracked or broken glass
front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panel(s) should be
done by a licensed or qualifi ed service per
son.

GLASS REPLACEMENT

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
®
dealer only.
Replacement glass is shipped already installed
into the door frame. Reinstall as per Glass Door
Installation in "Standard Flush Door" section.
CAUTION: Wear gloves when
removing damaged or broken
glass.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualifi ed service person.
44

BAY GLASS REPLACEMENT

1) Remove the door from the unit and place on
a soft surface to prevent scratching.
2) Remove the nuts holding the glass clips in
place and remove.
3) Replace the glass. The glass must have
gasketing around it.
4) Reverse the previous steps, replace the glass
clips and fasten with the nuts but do not over
tighten, as this can break the glass.
5) Replace door on the stove and check the
seal.

INSTALLING VALVE

1) Attach the valve to the valve bracket with
the 4 (m5x8 metric) screws provided.
2) Reconnect the "gas out" fl are fi tting with an
11/16" wrench.
3) Reconnect the "gas out" fl are nut with a
13/16" wrench.
4) Install piezo ignitor push button assembly
and reconnect wire.
5) Reconnect the quick drop out thermocouple
nut with a 9mm wrench.
6) Reconnect the pilot tube nut with a 7/16"
wrench.
7) Scrape off the old gasket from the fl oor of the
fi rebox and from the valve tray assembly.
8) Install a new gasket and reinstall the valve
tray assembly.
Note:
Failure to install a new gasket
may severely affect the appliance
performance.
9) Reinstall the 10 hold down screws.
10) Hook up the 2 TP and 2 TH wires to the
appropriate connections on the valve.
11) Reinstall the two bottom defl ectors and brick
panels.
12) Install burner and grate assembly.
13) Hook up the gas line and check for gas
leaks with a soap and water solution or a
gas leak detector. (Do not use open fl ame
for leak testing.)
14) Fire up the unit temporarily.
15) Check the manifold pressure.
16) Reinstall the logs and brick panels as
needed.
17) Close the door and replace the louvers.
18) Fire up the unit again and check for proper
fl ame appearance and glow on logs.
®
Regency
P48-2 Zero Clearance Direct Vent Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

P48-ng2P48-lp2

Table of Contents