Names and Functions of Parts
2.1.3 Operation mode setting switches
Normal use
Mode
(Factory default)
Switch
setting
SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4 SW1 SW2 SW3 SW4
OFF OFF OFF OFF OFF ON ON ON OFF ON OFF OFF OFF OFF ON OFF OFF ON ON OFF
Operation when selecting the memory clear menu display
• [Clear Memory] menu is displayed by selecting the memory clear menu display and turning
the power supply on.
• Press [GT Data] to clear data in the user memory.
• Press [Holding Data] to clear data in the hold memory.
• Press [PLC Backup Data] to clear data backed up using the PLC backup/restore function.
• When memory clear is complete, "Cleared" is displayed.
• For resetting the condition to the normal use, turn off the power supply, change the
operation mode setting switches to the normal use mode, and turn on the power supply
again.
• When "Reflect address / port setting to GT" is checked in [GT Configuration] > [GT
Communication Parameters] of GTWIN, the IP address of the GT is initialized when
executing memory clear processing.
REFERENCE
For information on the data stored in the user memory or hold memory, refer to
"6.1.2 Performance Specifications".
2-4
Memory clear
Inhibit system
menu display
menu shift
Inhibit system
Inhibit
menu shift &
Ethernet shift
Ethernet use
Inhibit