Parameter list
Parameter
 56
Current monitoring reference
 57
Restart selection
58
Free parameter 1
59
Free parameter 2
61
Key lock operation selection
 65
Retry selection
 67
Number of retries at fault occurrence
 68
Retry waiting time
 69
Retry count display erase
Reset selection/disconnected PU detection/
75
PU stop selection
 77
Parameter write selection
80
Voltage control proportional gain
81
Voltage control integral gain
82
Current control proportional gain
83
Current control integral gain
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
123
PU communication waiting time setting
124
PU communication CR/LF selection
 145
PU display language selection
168
169
Parameter for manufacturer setting. Do not set.
269
342
Communication EEPROM write selection
500
Communication error execution waiting time 0 to 999.8s

Communication error occurrence count
501

display
502
Stop mode selection at communication error 0, 3

542
Communication station number (CC-Link)
,,
543
Baud rate (CC-Link)
,,
544
CC-Link extended setting
,
C0(900)
FM terminal calibration

C1(901)
AM terminal calibration

989
Parameter copy alarm release
990
PU buzzer control
991
PU contrast adjustment
Pr. CL
Parameter clear
ALLC
All parameter clear
Er.CL
Fault history clear
PCPY
Parameter copy

Differ according to capacities. (55K or lower/75K or higher)

Differs according to the voltage class. (200V class/400V class)

Parameters which can be set when the plug-in option (FR-A7NC) is mounted.

The setting is applied after converter reset or at the next power-ON.

"L.ERR" LED on FR-A7NC flickers when a setting is changed. If the converter is reset, the setting is applied and LED turns off.

The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).
74
Name
0 to 500A/0 to 3600A
0, 9999
0 to 9999
0 to 9999
0, 10
0, 1, 2, 3, 4
0 to 10, 101 to 110
0.1 to 360s
0
0 to 3, 14 to 17
1, 2
0 to 1000%
0 to 1000%
0 to 200%
0 to 200%
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0 to 150ms, 9999
0, 1, 2
0 to 7
0, 1
0
1 to 64
0 to 4
0, 1, 12
10/100
0, 1
0 to 63
0, 1
0, 1
0, 1
0, 1, 2, 3
Range
Increments
0.01A/

0.1A
1
1
1
1
1
1
0.1s
1
1
1
1%
1%
1%
1%
1
1
1
1
1
1ms
1
1
1
0.1s
1
1
1
1
1
1
1
1
1
1
1
1
Initial
Refer to
Customer
value
page
Rated
84
current

9999
89
9999
90
9999
90
0
90
0
91
0
91
1s
91
0
91
14
92
2
94
100%
79
100%
79
100%
95
100%
95
0
97
192
97
1
97
2
97
1
97
9999
97
1
97
0
117
0
116
0s
115
0
115
0
115
1
109
0
109
0
109
118
118
10/100
121

1
117
58
117
0
120
0
120
0
134
0
121
setting