Rated Specifications - Mitsubishi Electric FR-HC2-7.5K Instruction Manual

Hide thumbs Also See for FR-HC2-7.5K:
Table of Contents

Advertisement

Rated specifications

6.1
Rated specifications
200V
Model name FR-HC2-K
Applicable inverter capacity (kW)
Rated output capacity (kW)

Rated input voltage (V)
Rated input current (A)
Overload current rating

Permissible power supply voltage fluctuation
Permissible power supply frequency fluctuation
Input power factor
Power supply capacity (kVA)
Protective structure of the converter
Cooling system
Approximate mass (kg)

400V
Model name FR-HC2-HK
Applicable inverter capacity (kW)
Rated output capacity (kW)

Rated input voltage (V)

Rated input current (A)
Overload current rating

Permissible power supply voltage
fluctuation
Permissible power supply
frequency fluctuation
Input power factor
Power supply capacity (kVA)
Protective structure of the
converter

Cooling system
Approximate mass (kg)


Model name of the 400V class ends with H.

The permissible voltage imbalance ratio is 3% or less. (Imbalance ratio = (highest voltage between lines - average voltage between three lines ) / average
voltage between three lines  100)

DC output capacity when the input voltage is 200VAC (400V for the 400V class)

Change the MC power supply stepdown transformer tap according to the input voltage. (Refer to page 51)

The % value of the overload current rating indicates the ratio of the overload current to the converter's rated input current. For repeated duty, allow time for
the converter and the inverter to return to or below the temperatures under 100% load.

The protective structure is IP40 for FR-DU07-CNV (except the PU connector) and IP00 for the outside box (220K or lower) and the reactor regardless of
their capacities.

When the hook of the converter front cover is cut off for installation of the plug-in option, the protective structure changes to the open type (IP00).

Mass of FR-HC2 alone.
148
7.5
7.5
10.7
Three-phase 200V to 220V 50Hz/200V to 230V 60Hz
33
14
Enclosed type (IP20)

7
7.5
15
30

7.5
15
30
11.0
20.2
37
17
31
57
323V to 506V 50/60Hz
14
26
47
Enclosed type
(IP20)

9
9
26
15
30
15
30
19.8
38
61
115
150% 60s
170V to 242V 50Hz
170V to 253V 60Hz
5%
0.99 or more (when load ratio is 100%)
25
47
Open type (IP00)

Forced air cooling
12
24
55
75
110
160
55
75
110
73
92
135
Three-phase 380V to 460V 50Hz/60Hz
110
139
203
150% 60s
323V to 460V 50/60Hz
5%
0.99 or more (when load ratio is 100%)
90
113
165
Open type (IP00)
Forced air cooling
43
37
56
55
75
55
75
71
92

215
278
170V to 230V
50Hz/60Hz
88
110
39
53
220
280
400
160
220
280
400
192
264
336
476

290
397
506
716
235
322
410
580
120
120
160
250
560
560
660
993
804
250