(2)
Output signal
Terminal
Type
Terminal Name
Symbol
Inverter run enable
RDY
signal
CVO
During converter run
Multi-purpose output
Y1
1
Multi-purpose output
Y2
2
RSO
Converter reset
Open collector output
SE
common
FM
For meter
AM
Analog signal output
Analog signal output
5
common
A, B, C
Fault contact
MC connection
88R, 88S
terminal
(3)
Output signals of FR-HC2 dedicated board
Terminal
Type
Terminal Name
Symbol
Multi-purpose output
Y3
3
Open collector output
SE2
common
Communication 
(4)
Terminal
Type
Terminal Name
Symbol
PU connector
 USB connector and RS-485 terminal block cannot be used.
Description
Turns ON at alarm occurrence and reset (RES) signal input.
Connect this terminal to the terminal MRS or a terminal where
the X10 signal is assigned to in the inverter.
Turning ON RDY signal stops the inverter.
RYD signal OFF: Inverter can run
RYD signal ON: Inverter cannot run
Signal is output during harmonic suppression.
Output item: OL signal (overload alarm) (initial setting)
Turns ON at an occurrence of overcurrent (150% overload or
more).
Output item: PHS signal (power phase detection) (initial
setting)
Turns ON when power phase detection is locked.
Turns ON at a converter reset (RES-ON).
Connect this terminal to the inverter terminal of which RES
signal is assigned to.
Reset the connected inverter by turning ON the RSO.
Common terminal for the terminals RDY, CVO, OL, Y1, Y2
Connect it to the inverter terminal SD (sink logic).
Select one monitor item from multiple monitor items such as
input current and bus voltage. Not output during a converter
reset.
The output signal is proportional to the magnitude of the
corresponding monitoring item.
Monitor item can be switched by ON/OFF of terminals X1 and
X2.
Common terminal for analog signal output
1 changeover contact output indicates that the converter's
protective function is activated and the output is stopped.
Fault: No conduction across B and C (Conduction across A
and C),
Normal: Conduction across B and C (No conduction across A
and C)
Controls the MC for the limit resistor.
Description
Output item: Y5 signal (output voltage match) (initial setting)
Turns ON when the detected bus voltage equals to the
commanded bus voltage.
Common terminal for terminal Y3
With the PU connector, communication can be made through RS-485. (for
connection on a 1:1 basis only)
Conforming standard : EIA-485 (RS-485)
Transmission format : Multidrop
Communication speed : 4800 to 38400bps
Overall length : 500m
Wiring of control circuit
Permissible load 24VDC
(27VDC maximum) 0.1A (A
voltage drop is 2.8V maximum
when the signal is ON.)
Permissible load current 2mA
At rated input current of the
converter: 1440 pulses/s
Output signal 0 to 10VDC
Permissible load current 1mA
Load impedance 10k
Contact capacity AC230V
0.3A
(Power factor=0.4)
30VDC output 0.3A
Permissible load: 24VDC 0.1A
Description
Rated Specifications
2
Rated Specifications
Refer to
page
95
59