Page 11
Thank you for choosing this Mitsubishi Inverter option. This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum. Please forward this instruction manual to the end user.
Page 12
4. Additional Instructions 2) Trial run Also note the following points to prevent an Caution accidental failure, injury, electric shock, etc. Assumes that incorrect handling may cause Before starting operation, confirm and an accidental failure, injury, electric shock, adjust the parameters. A failure to do so etc.
Unpack the option unit, and ensure that the product received is as you ordered and it is intact. DC REACTOR MODEL FR-HEL-N XXXXXXXXXXXX SERIAL MITSUBISHI ELECTRIC CORP. FR-HEL- N Applied motor capacity (kW) Symbol Applied power supply voltage 690 V class Installation (1) Install the reactor horizontally or vertically according to the environment conditions specified on page 5.
Wiring Wiring (1) Connect the reactor across terminals P and P1 of the inverter. Minimize the connection cable between the reactor and inverter so that the length is within 5 m. (For the size of the cable, refer to page 4) FR-HEL The connection cable should be 5 m maximum.
* The power factor is calculated on the assumption that the power impedance is 1%. The value changes according to the power supply capacity and power impedance. Outline Dimension Drawings FR-HEL-N280K, N315K 2-M8 eye nut 4-mounting hole...
Page 22
●グローバルFAセンター ●上海FAセンター ●インドネシアFAセンター ●メキシコFAセンター MITSUBISHI ELECTRIC AUTOMAITON PT. MITSUBISHI ELECTRIC INDONESIA MITSUBISHI ELECTRIC AUTOMATION, INC. (CHINA) LTD. Cikarang Office Mexico Branch No.1386 Hongqiao Road, Mitsubishi Electric Jl. Kenari Raya Blok G2-07A Delta Silicon 5, Mariano Escobedo #69, Col. Zona Industrial, Automation Center, Shanghai, China Lippo Cikarang - Bekasi 17550, Indonesia Tlalnepantla Edo, C.P.54030, Mexico TEL. 86-21-2322-3030 FAX. 86-21-2322-3000 (9611#) TEL. 62-21-2961-7797 FAX. 62-21-2961-7794 TEL. 52-55-3067-7511 ●ブラジルFAセンター ●北京FAセンター ●ハノイFAセンター MITSUBISHI ELECTRIC DO BRASIL MITSUBISHI ELECTRIC AUTOMATION MITSUBISHI ELECTRIC VIETNAM COMPANY COMERCIO E SERVICOS LTDA. (CHINA) LTD. Beijing Office LIMITED Hanoi Branch Rua Jussara, 1750- Bloco B Anexo, Jardim Unit 901, 9F, Office Tower 1, Henderson 6 - Floor, Detech Tower, 8 Ton That Thuyet Santa Cecilia, CEP 06465-070, Barueri - SP, Centre, 18 Jianguomennei Avenue, Street, My Dinh 2 Ward, Nam Tu Liem District, Brasil Dongcheng District, Beijing, China Hanoi, Vietnam TEL. 55-11-4689-3000 FAX. 55-11-4689-3016 TEL. 86-10-6518-8830FAX. 86-10-6518- TEL. 84-24-3937-8075 FAX. 84-24-3937- 2938 8076 ●ブラジル・ボイトゥバFAセンター...