6.2

Common specifications

Control method
Power supply frequency range
Current limit level
Input signal (Five terminal)
Output signal
Open collector output (Five terminals)
Relay output (One terminal)
Operating status
For meter
Pulse train output
(Max. 2.4kHz: one terminal)
Analog output
(Max. 10VDC: one terminal)
Operating
Operation panel
status
(FR-DU07-CNV)
Fault record
Parameter unit
(FR-PU07)
Interactive
guidance
Protective
function
Protective/warning
function
Warning
functions
Surrounding air temperature
Ambient humidity
Storage temperature

Atmosphere
Altitude/ vibration

Can be displayed only on the operation panel (FR-DU07-CNV).

Can be displayed only on the option parameter unit (FR-PU07).

Temperature applicable for a short time, e.g. in transit.

This protective function is not available in the initial status.

This protective function is enabled when FR-A7NC is mounted.
2

2.9m/s
or less for the 160K or higher.
PWM control
50Hz to 60Hz
Current limit value selectable (0 to 220% variable)
The following signals can be assigned to Pr. 3 to Pr. 7 (input terminal function selection):
converter stop, monitor switching, converter reset, external thermal relay, and inrush
resistance overheat detection.
The following signals can be assigned to Pr. 11 to Pr. 16 (output terminal function selection):
inverter run enable signal, converter reset, converter running, overload alarm, power
supply phase detection, output voltage match, instantaneous power failure detection,
regenerative drive recognition, electronic thermal relay pre-alarm, fan alarm, heatsink
overheat pre-alarm, during retry, input current detection, zero current detection, life alarm,
maintenance timer, instantaneous power failure detection hold, alarm, and fault output.
The following signals can be assigned to Pr. 54 FM terminal function selection (pulse train
output) and Pr. 50 AM terminal function selection (analog output): power supply frequency,
input current, input voltage, converter output voltage, electronic thermal relay load factor,
input power, reference voltage output.
Power supply frequency, input current, input voltage, fault or alarm indication, converter
output voltage, electronic thermal relay load factor, cumulative energization time,
cumulative power, input power, input power (with regenerative display), I/O terminal
status
, power/regenerative drive indication
*1
Fault definition is displayed when a fault occurs. Past eight fault records and the data right
before the fault (input voltage/current/bus voltage/cumulative energization) are stored.
Function (help) for operation guide

Overcurrent, overvoltage, converter protection thermal, fin overheat, instantaneous power
failure, undervoltage, input phase loss, HC2 dedicated board disconnection, input power
supply fault, external thermal relay operation
retry count excess
converter CPU fault, operation panel power supply short circuit,
,
24VDC power output short circuit, input current detection value exceeded
current limit circuit fault, internal circuit fault, option fault
Fan alarm, overload signal detection, electronic thermal relay pre-alarm, PU stop,
maintenance timer alarm
lock, parameter copy alarm, no-phase detection
-10C to +50C (non-freezing)
90%RH or less (non-condensing)
-20C to +65C
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Maximum 1,000m above sea level, 5.9m/s
axes)
Common specifications
, parameter error, PU disconnection

, communication option fault

, parameter write error, copy operation error, operation panel

2
or less
at 10 to 55Hz (directions of X, Y, Z

,

, inrush

.

6
149