5. Referring to the tables below, set up the radar.
[Radar] menu - [Radar Initial Setup]
Menu item
[Antenna Rotation]
[Antenna Heading Align]
[Main Bang Suppression]
[Enable Sector Blanking]
[Enable Sector 2 Blanking]
[Radar] menu - [Antenna Position]
Menu item
[Longitudinal (from bow)]
[Lateral (-Port)]
[Antenna Height]
[Auto Tuning]
[Tuning Source]
[Manual Tuning]
[Radar Monitoring]
[Radar Optimization]
[ARPA Advanced Settings]
[Set Hardware To Factory
Default]
[Reset Default Settings]
Select the antenna rotation speed.
See "How to align the antenna heading" on page 19.
If main bang appears at the screen center, slide the circle
icon so that the main bang disappears, while watching the
radar echo at the left-hand side of the display.
Up to two sectors may be selected for blanking (no trans-
mission). Select [ON] to enable this feature. Set the start
and end angles (0° to 359°).
Referring to the figure on the right, enter
the radar antenna positioning bow-stern
(Longitudinal) and port-starboard (Lateral)
position from the origin.
Select the height of the antenna above the waterline.
Enable/disable auto tuning for the connected radar.
For dual-range display, select the range to use as the
manual tuning source.
Manually tune the radar. Not available when [Auto Tuning]
is enabled.
Display various information regarding the connected ra-
dar.
Automatically adjust magnetron output and tuning for the
connected radar.
Note: Be sure to perform [Radar Optimization] after re-
placing the magnetron.
Do not change these settings.
Resets the radar selected at [Radar Source] to factory de-
fault.
Resets [Radar] menu settings to default.